Gen Runs but Not creating power


hey all;

So my 2003 carver 396 with Onan generator was launched. The marina launched it while i was away. When I came to the boat, the Generator was turned off at the generator itself (not the remote start switch at the power panel). I mention this as I have never turned off the generator there so am assuming the staff did this. After rectifying that issue I got the generator to run and it runs perfectly fine, but will NOT provide power at the panel.

it sure seems like there is a breaker popped or fuse blown that I am unaware of. things I have checked:

* at the generator, the field breaker is normal.
* at the generator, the 75 amp breaker is normal
* battery on/off switch is verified ON
* Power panel was triple checked and no voltage or amp pull no mater what I do.

Any thoughts on something I could have missed?