Kohler generator for dummies, questions
- sep4086
- Scurvy Dog

- Posts: 18
- Joined: November 6th, 2015, 6:34 pm
- Vessel Info: 1990 3867 SANTEGO
2003 PRO LINE 26 WALK - Location: LAKE MICHIGAN
- Has thanked: 2 times
- Been thanked: 1 time
Re: Kohler generator for dummies, questions
To me it sounds like the water pump impeller might be weak and needs to be replaced. If you have good water flow out the exhaust pipe then maybe the thermostat or the high temperature sensor might be bad.
- Keith S
- Scurvy Dog

- Posts: 36
- Joined: October 4th, 2017, 6:02 pm
- Vessel Info: 2005 38 Super Sport
- Location: Oceanport, NJ
- Been thanked: 21 times
Re: Kohler generator for dummies, questions
I would suggest that when someone is looking for advice on a generator to post the exact model you have. I work on these for a living and each model has it's own quirks and issues. What may be great advice for one model may have nothing to do with a different model. Of course generic things like replace the impeller regularly apply to all.
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
Re: Kohler generator for dummies, questions
++1
Always best to provide as much information about the hardware as possible.
Always best to provide as much information about the hardware as possible.
- Helmsman
- Commander

- Posts: 323
- Joined: May 9th, 2016, 9:16 am
- Vessel Info: Temporarily Boatless
- Has thanked: 73 times
- Been thanked: 42 times
Re: Kohler generator for dummies, questions
glazingguru wrote:Qr Bbpost Well, I figured it out and it wasnt that hard. HOWEVER, the damn thing still ran for a while and then shut itself off. I couldnt figure it out so I asked a mechanic to look at it. Come to find out, the wet muffler was shot and leaking into the bilge. The guy said it was even possible it could leak while not being run??? Anyway, I am replacing it and I hope that cures the problem with it shitting itself off because I suspect it was overheating.
I had the problem with the Benny shutting off last year on a Kohler 7.3E. Turned out, all it was, was that the oil level was low. Evidently, they don’t like being run with the oil low just a little.
- mjk1040
- Admiral

- Posts: 1531
- Joined: July 30th, 2015, 8:15 am
- Vessel Info: 1998 355 AC/MY "Deja Vu"
- Location: Savannah, NY
- Has thanked: 9 times
- Been thanked: 248 times
Re: Kohler generator for dummies, questions
Glazerguru, in ur original post u stated u shut the shore power off at the panel. The Panel mains have to be on in order to get electric from the generator. U should have a relay in the system that automatically switches from shore power supply to genny power supply. Or you can unplug the shore power to be sure. I just serviced our 1998 kohler genny and by the looks of things the impleller may have been changed once in 20 years. It was in bad shape. Fuel filter was original and I was unable to remove the anode pencil, all I got was the threaded brass end. That being said I try and run the genny every time we can with a load on it. U got to use it or u will lose it.
Mike
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
- The Dash
- Scurvy Dog

- Posts: 11
- Joined: February 22nd, 2017, 12:41 pm
- Vessel Info: 1987 Carver 42Aft Cabin
- Has thanked: 3 times
Re: Kohler generator for dummies, questions
Keith S, I have a problem with the original generator of my 1987 42 Aft Carver. The model is Kohler 7.5R27, Spec 106276A. Aside from its vintage making it hard to find replacement parts, the generator starts but only keeps running if I exercise the fuel pump priming lever. I replaced the fuel pump with aTacit electric cube style pump, now it won't start at all.
Any suggestions?
Any suggestions?
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times
Re: Kohler generator for dummies, questions
The fuel is polarity sensitive. If it runs backwards it doesn't pump any fuel. Try switching the polarity.
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times
- mjk1040
- Admiral

- Posts: 1531
- Joined: July 30th, 2015, 8:15 am
- Vessel Info: 1998 355 AC/MY "Deja Vu"
- Location: Savannah, NY
- Has thanked: 9 times
- Been thanked: 248 times
Re: Kohler generator for dummies, questions
I thought you were being a Smart A** Tom!
Last edited by mjk1040 on April 19th, 2018, 7:48 pm, edited 1 time in total.
Mike
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times