Welcome to Carver Yachts Owners Forum

We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com

You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Main AC breaker trips on shore power only?

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author United States of America
CptBacardi
Deck Hand
Deck Hand
Posts: 93
Joined: June 11th, 2017, 5:02 pm
Vessel Info: 1989 Carver 38 Santego (not an aft cabin)
Location: Texas
Has thanked: 3 times

Main AC breaker trips on shore power only?

Postby CptBacardi » July 21st, 2018, 12:02 am

Hi! The drama continues. I was on shore power using a heat gun to shrink wrap some butt connectors and the main AC breaker tripped. It tripped again when I tried to turn it back on. I turned off all breakers in that circuit and tried the main again, and it stays on. I show 120v when doing that. If I turn on ANY breaker in that circuit, even if it’s not being used, the main breaker trips again. I did that all on shore power. As a test, I started the gen set, and tried switching to ship power. Everything works fine on ship power. Breakers all work. I do the same sequence for shore power again and it still doesn’t work, does the same thing. Uuuh, what do I do now? Is the switch that controls ship/off/shore power bad now or something?
You do not have the required permissions to view the files attached to this post.
1989 Carver 38 Santego

User avatar

United States of America
RGrew176
Admiral
Admiral
Posts: 6388
Joined: August 17th, 2015, 4:07 am
Vessel Info: 2022 Stingray 182 SC
Location: Southgate, MI.
Has thanked: 72 times
Been thanked: 467 times

Re: Main AC breaker trips on shore power only?

Postby RGrew176 » July 21st, 2018, 12:06 am

There are a lot of really smart and experienced people here. Someone will be able to assist. Unfortunately I am not that person. My electrical knowledge is very limited.
Rick Grew

2022 Stingray 182 SC

2004 Past Commodore
West River Yacht & Cruising Club
User avatar

Topic author United States of America
CptBacardi
Deck Hand
Deck Hand
Posts: 93
Joined: June 11th, 2017, 5:02 pm
Vessel Info: 1989 Carver 38 Santego (not an aft cabin)
Location: Texas
Has thanked: 3 times

Re: Main AC breaker trips on shore power only?

Postby CptBacardi » July 21st, 2018, 1:26 am

Hey, an easy fix for a change! I reseated the main 50 amp shore power cable and now it works. Go figure!!
1989 Carver 38 Santego
User avatar

United States of America
km1125
Admiral
Admiral
Posts: 3500
Joined: February 28th, 2017, 6:04 pm
Has thanked: 69 times
Been thanked: 1043 times

Re: Main AC breaker trips on shore power only?

Postby km1125 » July 21st, 2018, 10:40 am

The issue probably was with the "reverse polarity protection" part of the breaker. On generator, there's really no "hot" and "neutral" out of the generator.... you actually designate that when it's wired into something. On shore power, you have to live by what the power company has designated "hot" and "neutral". The breaker looks at the voltage differences between the hot, neutral and ground and it looked like the neutral had power, so it tripped the breaker.

You should make sure the connections on that cord and socket are clean and not corroded. You should also place a big load on there - run everything you can to try and get close to 50A load. Then feel the connector to see if it's warm at all. If it is, you have a poor connection somewhere inside and you need to fix that before it becomes a hazard.

Return to “Electrical”