1987 3607 blower question

Post by RWS »

1987 3607, did it come with 1 or 2 blowers? My boat has 2 and if you turn on from the bridge and then also turn on lower helm switch it sounds like they either sped up or the 2nd one comes on. Are they wired separate or does turning on lower helm switch also push more electrical current to them and increase their speed? Some things will drive you crazy about a boat.
User avatar
BenTen
First Mate
First Mate
Posts: 106
Joined: August 11th, 2018, 8:59 pm
Vessel Info: 1984 Carver 3697 Mariner - "We'll Sea"
Has thanked: 20 times
Been thanked: 32 times

Re: 1987 3607 blower question

Post by BenTen »

I don't know about your boat specifically, but have you tried looking at the wiring diagram from Carver? I'm sure they are still available. It sounds like someone changed the wiring or you have some corrosion in the wire from one of the switches (higher resistance = less current and more heat).
Thanks,
Ben in SC
User avatar
km1125
Admiral
Admiral
Posts: 3658
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 1987 3607 blower question

Post by km1125 »

There are two blowers and they both come on at the same time with either the lower station switch or the bridge switch.

What you are hearing is the difference in voltage drop. With both switches on you are essentially doubling up the wire going to the blowers which cuts the resistance in half, allowing a slightly higher voltage to run the blower. It is normal.
User avatar
RWS
Deck Hand
Deck Hand
Posts: 60
Joined: March 18th, 2019, 10:00 pm
Vessel Info: 1987 3607 aft
Location: Knoxville.TN
Has thanked: 28 times
Been thanked: 1 time

Re: 1987 3607 blower question

Post by RWS »

km1125 wrote:QR_BBPOST There are two blowers and they both come on at the same time with either the lower station switch or the bridge switch.

What you are hearing is the difference in voltage drop. With both switches on you are essentially doubling up the wire going to the blowers which cuts the resistance in half, allowing a slightly higher voltage to run the blower. It is normal.
Is it hard on the blower motor to have both on?
User avatar
km1125
Admiral
Admiral
Posts: 3658
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 1987 3607 blower question

Post by km1125 »

RWS wrote:QR_BBPOST
km1125 wrote:QR_BBPOST There are two blowers and they both come on at the same time with either the lower station switch or the bridge switch.

What you are hearing is the difference in voltage drop. With both switches on you are essentially doubling up the wire going to the blowers which cuts the resistance in half, allowing a slightly higher voltage to run the blower. It is normal.
Is it hard on the blower motor to have both on?
No, not at all. The motors are cooled by the flowing air. More current make more heat but also more air moving though to take care of it.