Any chance anyone has a copy of the Kohler 6.5cz Service Manual
1993 Kohler 6.5CZ23 only runs while holding start button
- jeffnnoble
- Scurvy Dog

- Posts: 6
- Joined: July 27th, 2021, 6:41 am
- Vessel Info: 1993 Carver 350 Aft
- Location: Grand Haven Mi.
- Has thanked: 11 times
- Been thanked: 3 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
Last edited by jeffnnoble on July 29th, 2021, 11:34 am, edited 2 times in total.
- jeffnnoble
- Scurvy Dog

- Posts: 6
- Joined: July 27th, 2021, 6:41 am
- Vessel Info: 1993 Carver 350 Aft
- Location: Grand Haven Mi.
- Has thanked: 11 times
- Been thanked: 3 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
Thanks for your reply's please bare with me as I have a few additional questions that I will preface with; electronics have been a bit of a nemesis for me.
Tom, Thanks for your reply. Can you expand on what indicator/s lead you to think capacitor? Asking because I'm not sure of the role of the capacitor is in this system hoping you can shed some light.
Midnightsun, Do you know if the oil pressure switch is open or closed when the Kohler generator is OFF (not running)? Asking because "The oil pressure sensor simply makes contact to ground when pressure is detected." appears to be opposite of the video. I'm ok with either just confused if the switch in this application should be open or closed when the generator is off.
For what it is worth the wiring diagram shows a drawing of a closed oil pressure switch, the same diagram also shows the other safety switches (one Engine switch & two Exhaust temp switches as open)
Tom, Thanks for your reply. Can you expand on what indicator/s lead you to think capacitor? Asking because I'm not sure of the role of the capacitor is in this system hoping you can shed some light.
Midnightsun, Do you know if the oil pressure switch is open or closed when the Kohler generator is OFF (not running)? Asking because "The oil pressure sensor simply makes contact to ground when pressure is detected." appears to be opposite of the video. I'm ok with either just confused if the switch in this application should be open or closed when the generator is off.
For what it is worth the wiring diagram shows a drawing of a closed oil pressure switch, the same diagram also shows the other safety switches (one Engine switch & two Exhaust temp switches as open)
- bud37
- Admiral

- Posts: 5182
- Joined: April 23rd, 2015, 10:22 pm
- Has thanked: 604 times
- Been thanked: 1312 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
Jeff, is that schematic something you could post here........I am sure there are a few things that could cause your problem other than the sensor so you will have to cross things off as you go in my opinion.....tough to diagnose in a forum setting.
FWIW.....The above is just my opinion.
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
With a bad capacitor, it wont generate output voltage. Without output voltage, your run relay will not latch. Capacitor should be less than $10.
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
A few good thoughts here for sure, could be a few things. Don't rule out a bad Start/Stop switch though. Having a faulty one at either end will cause the same symptom no mater which switch you try to use. I had this symptom on a Kohler but can't remember the model. A real head scratcher because I checked just about everything including the remote switch at the panel. Finally decided to also do a continuity test on the switch at the unit and that's what it turned out to be, replaced it and all good.
- jeffnnoble
- Scurvy Dog

- Posts: 6
- Joined: July 27th, 2021, 6:41 am
- Vessel Info: 1993 Carver 350 Aft
- Location: Grand Haven Mi.
- Has thanked: 11 times
- Been thanked: 3 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
Thanks to all who took the time to read this series of posts.
GOOD NEWS! We are up and running again!
After Reading the additional replies from July 29th and doing more research on each as luck would have it Tom was on to something. In my original post I indicated that while holding the start switch I was getting no voltage. Upon inspection the capacitor looked fine, and did not have any short to ground from either terminal. I did however notice with my multimeter that there was no stored volts AC or DC. The side of the capacitor was rated for 1000 VDC or 440VAC so using a 9V battery tried to introduce voltage to see if the capacitor would hold or store voltage, and it would not. I was able to locate a replacement at a local Kohler dealer, and on a Saturday morning too! As Luck would have it as I was exiting the Kohler repair tech had just stopped in to pick up parts for a repair he was in the middle of. Giving me a few minutes of his time and running down my story, basically my initial post, he interrupted me at no output voltage and said I need to "replace the capacitor." "99.9% of the time a situation like mine with no output voltage is a bad capacitor." Showing him what I had just purchased he replied "That'll do it! which is a good thing because I'm booked out foe the next 6 weeks."
also for those interested the LED1 is the run circuit that Tom mentioned above and will illuminate with output voltage.
GOOD NEWS! We are up and running again!
After Reading the additional replies from July 29th and doing more research on each as luck would have it Tom was on to something. In my original post I indicated that while holding the start switch I was getting no voltage. Upon inspection the capacitor looked fine, and did not have any short to ground from either terminal. I did however notice with my multimeter that there was no stored volts AC or DC. The side of the capacitor was rated for 1000 VDC or 440VAC so using a 9V battery tried to introduce voltage to see if the capacitor would hold or store voltage, and it would not. I was able to locate a replacement at a local Kohler dealer, and on a Saturday morning too! As Luck would have it as I was exiting the Kohler repair tech had just stopped in to pick up parts for a repair he was in the middle of. Giving me a few minutes of his time and running down my story, basically my initial post, he interrupted me at no output voltage and said I need to "replace the capacitor." "99.9% of the time a situation like mine with no output voltage is a bad capacitor." Showing him what I had just purchased he replied "That'll do it! which is a good thing because I'm booked out foe the next 6 weeks."
also for those interested the LED1 is the run circuit that Tom mentioned above and will illuminate with output voltage.
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
Thanks for following up. Glad you solved the issue 
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times
Re: 1993 Kohler 6.5CZ23 only runs while holding start button
Luck? I think not
Glad your back to generating!
Glad your back to generating!
- rcaron
- Scurvy Dog

- Posts: 1
- Joined: February 5th, 2022, 5:02 pm
- Vessel Info: 2005 Voyager 56 D12 Volvo Penta Kholer 23 KW Generator Loaded
- Location: Kemah Texas
Re: 1993 Kohler 6.5CZ23 only runs while holding start button