Shower Sump DC breaker size

Post by tonyiiiafl »

1994 390CPMY. Shower sump trips breaker occasionally. Pump is new, so I am suspecting a weak breaker. I have the manuals at home, so I am sure I can find the proper size. However, does anyone know how to get it out of the panel? Looks like there is a catch on right side and a screw holding the breaker to the buss bar. . I slid the catch out but couldn’t get the breaker out. Also any idea of replacement source?
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: Shower Sump DC breaker size

Post by bud37 »

Sorry but have to ask......you did remove the two screws holding it to the panel from the front ??...... ;-)
FWIW.....The above is just my opinion.
User avatar
tonyiiiafl
Admiral
Admiral
Posts: 902
Joined: November 19th, 2015, 4:00 am
Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
Location: Cape Cod, MA
Has thanked: 601 times
Been thanked: 193 times

Re: Shower Sump DC breaker size

Post by tonyiiiafl »

Never be sorry! Mine have no screws holding them to the panel. Take the front panel off and the screw holes are empty. it appears the breaker is slid onto the buss bar on left, and a red clip on right. After a little research, looks like a Carling D or G series.
image.jpg
You do not have the required permissions to view the files attached to this post.
User avatar
km1125
Admiral
Admiral
Posts: 3657
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: Shower Sump DC breaker size

Post by km1125 »

Before you go buy a new one, why don't you swap it with another similarly-rated breaker? That should tell you if it's the breaker or if it's something in the circuit that's causing it to blow.
User avatar
tonyiiiafl
Admiral
Admiral
Posts: 902
Joined: November 19th, 2015, 4:00 am
Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
Location: Cape Cod, MA
Has thanked: 601 times
Been thanked: 193 times

Re: Shower Sump DC breaker size

Post by tonyiiiafl »

Good point. First I need to figure out how to remove it.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: Shower Sump DC breaker size

Post by tomschauer »

You don't need to remove it.
Just move the wire to another breaker
User avatar
tonyiiiafl
Admiral
Admiral
Posts: 902
Joined: November 19th, 2015, 4:00 am
Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
Location: Cape Cod, MA
Has thanked: 601 times
Been thanked: 193 times

Re: Shower Sump DC breaker size

Post by tonyiiiafl »

OUTSTANDING thought! Thank you!
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Shower Sump DC breaker size

Post by Viper »

I second Bud's thought, check your wiring and connections before condemning the breaker, they do fail on occasion but it's usually the last resort only after confirming everything else in the circuit is okay. I assume you replaced the pump with the same model and amp rating as the old one?
User avatar
tonyiiiafl
Admiral
Admiral
Posts: 902
Joined: November 19th, 2015, 4:00 am
Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
Location: Cape Cod, MA
Has thanked: 601 times
Been thanked: 193 times

Re: Shower Sump DC breaker size

Post by tonyiiiafl »

I replaced with same a year ago.