Bilge pumps run in the On position. Do not run in Auto. Suspected bad float switch so cut the wires to one and tied them together. Still no go.
Any thoughts?
Bob
Bilge pumps, on-off-auto, Santego 3867
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: Bilge pumps, on-off-auto, Santego 3867
If you have a switch with off in the middle and it's working as you described. I suspect the 12v positive is not on the common terminal on the switch. Heres a simple diagram.
You do not have the required permissions to view the files attached to this post.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- km1125
- Admiral

- Posts: 3657
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 81 times
- Been thanked: 1114 times
Re: Bilge pumps, on-off-auto, Santego 3867
There should be a separate breaker for the "auto" position and it might not be located in the main panel. Look around your main DC power switch to see if there are additional breakers there.
- ColRon
- Admiral

- Posts: 581
- Joined: April 24th, 2017, 6:06 pm
- Vessel Info: 1989 Carver Santego 3867
“Escape Plan” - Location: Murray, KY
- Has thanked: 77 times
- Been thanked: 157 times
Re: Bilge pumps, on-off-auto, Santego 3867
You have two sets of breakers for the bilge pumps. One on the circuit breaker panel on the starboard side. There is also another set of breakers and switch’s for the bilge pumps in the bottom step at the battery selector switch.
Ron
1989 Carver Santego 3867
“Escape Plan”
Murray, KY

1989 Carver Santego 3867
“Escape Plan”
Murray, KY
- bobwhorn
- Deck Hand

- Posts: 63
- Joined: February 18th, 2023, 1:18 pm
- Vessel Info: 1989 Carver Santego 3867. Repowered with Cat 3116s in 1993.
- Location: Texas
- Has thanked: 3 times
- Been thanked: 1 time
- Contact:
Re: Bilge pumps, on-off-auto, Santego 3867
ColRon you nailed it. It was the switches in the bottom step. One question remains: WHY?
- km1125
- Admiral

- Posts: 3657
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 81 times
- Been thanked: 1114 times
Re: Bilge pumps, on-off-auto, Santego 3867
Why what??
The location? Or why are there two? It's because the different breakers draw power from different places... one before the master switch and one after.
The location? Or why are there two? It's because the different breakers draw power from different places... one before the master switch and one after.