The boat I am looking at has 2/16000BTU AC units
My question is this enough to cool the forward cabin,main cabin and the aft cabin during the really HOT SUMMER days???
User avatar
Lyndon670
Admiral
Admiral
Posts: 657
Joined: July 29th, 2013, 11:35 pm
Vessel Info: 2000 Carver 506
Volvo TAMD74EDC
Location: Georgian Bay
Has thanked: 124 times
Been thanked: 140 times

Re: 405/406 air conditioning

Post by Lyndon670 »

Its never a problem to cool the aft cabin or forward cabin. You just close the cabin doors. Because there is no windows beyon tiny portligts and that they are at water level, they will cool quickly and stay cool. The main salon will be your issue. Keep the blinds closed and get front window covers and you will be fine.
Lyndon,
2000 Carver 506
FOXY JOE
Volvo 7.4TAMD
Queens Cove Marina
Georgian Bay, Ontario
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: 405/406 air conditioning

Post by Viper »

Interesting that there are only 2 units. Is this common for a 405? Ambient cabin temps are a large factor and as Lyndon said, if you have the sun shining in, it'll make it that much more difficult to bring temps down.
User avatar
dsolo
First Mate
First Mate
Posts: 193
Joined: October 24th, 2016, 2:56 am
Vessel Info: 1997 Carver 405 MY
454 EFI Crusaders
Name: La Belle ll
Location: Onekama, Michigan
Has thanked: 68 times
Been thanked: 25 times

Re: 405/406 air conditioning

Post by dsolo »

My 1997 405 has 3 AC units. One 16K btu located in the salon, a 9K btu located in the aft stateroom, and a 6K unit in the forward stateroom. I have no experience with their performance or ability to keep the vessel cool??. I purchased the boat in late October. See me in July/August.
dsolo
Vessel "LaBelle"
Portage Point Inn & Marina, Onekema, Mi
1997 Carver 405 MY
454 EFI Crusaders
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: 405/406 air conditioning

Post by Viper »

dsolo wrote:Qr Bbpost My 1997 405 has 3 AC units....

The number of units was either an option or perhaps one was removed and never replaced? Perhaps Kenny remembers Carver's offerings for the model.
User avatar
g36
Admiral
Admiral
Posts: 2115
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 654 times

Re: 405/406 air conditioning

Post by g36 »

heres my expereience i have a 405 and live in tennessee mid to upper 90s and lots of humidity and many nites in the 80's in the summer and i can tell you that the 2 ac units will not be enough to sleep comfortably . the salon and small forward stateroom are no problem i did alter the orignal design a bit but because the way the 405 has it the forward ac unit dumps air into both places fwd and salon areas the problem actually is the aft cabin. my 405 has one rectangular vent over the port side locker fed from the salon and it does marginal job for day time but trying to sleep forget it even with the door open and a fan blowing air in the door to help cool it theres just not enough air flow to the space .the electrical panel was ready for 3 but the boat was only orginally equipped with 2. relocated the thermostat to the salon where it should be and i added a mermaid 5200 ac/heat to the aft cabin and it handles the temp fine no problems. close the door while sleeping now and thermostat will control that zone and you wont have to try and keep the rest of the boat like a meat locker to get the aft cabin cool. youll be much happier with 3 unit imo
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
User avatar
Mystic144
Scurvy Dog
Scurvy Dog
Posts: 20
Joined: January 5th, 2016, 9:53 pm
Location: Mystic Ct
Has thanked: 1 time
Been thanked: 2 times

Re: 405/406 air conditioning

Post by Mystic144 »

Thanks for the input
Where in the aft cabin would you locate another AC unit?
User avatar
dsolo
First Mate
First Mate
Posts: 193
Joined: October 24th, 2016, 2:56 am
Vessel Info: 1997 Carver 405 MY
454 EFI Crusaders
Name: La Belle ll
Location: Onekama, Michigan
Has thanked: 68 times
Been thanked: 25 times

Re: 405/406 air conditioning

Post by dsolo »

The aft AC unit in my boat is located under the bed platform. It is the 9k btu unit. There is a thermostat in the room.

I am somewhat concerned about the salon AC unit. It draws make up air from a grill located perpendicular to the coil intake. The coil is right up against a salon wall. The wall is behind the salon sofa. There might be a 3/4" between the wall and the air flow for the coils? I found the coil and cooling fins covered with dust and carpet lint.
The fan is trying to pull air through the perpendicular grill opening and the 3/4" narrow space. I am considering opening the wall behind the sofa and having the air drawn directly onto the coil. The sofa may need to come away from the wall an inch or two. I need to see how things work this summer. Lots to review.
dsolo
Vessel "LaBelle"
Portage Point Inn & Marina, Onekema, Mi
1997 Carver 405 MY
454 EFI Crusaders
User avatar
Mystic144
Scurvy Dog
Scurvy Dog
Posts: 20
Joined: January 5th, 2016, 9:53 pm
Location: Mystic Ct
Has thanked: 1 time
Been thanked: 2 times

Re: 405/406 air conditioning

Post by Mystic144 »

Hi dsolo
Thanks for your comment on the location of the aft stateroom AC. Makes perfect sense for the aft cabin to have it's own unit.
As for the salon unit with the air feed behind the couch just does not seem that the unit is getting enough air supply. Without adequate air the unit can not operate as designed.
Please let me know what you do to rectify this.
Thanks
Rene
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: 405/406 air conditioning

Post by tomschauer »

My 355 is a bit smaller than your 405. I have a 16k unit that serves the salon and forward state room and a 12k unit that serves the aft cabin and also has diffuser serving the salon. During 90 or 90+ sunny days I will loose some ground and it may hit 75-77 in the salon, but as soon as the sun drops, I could hang meat anywhere in the boat if I wanted to set it low enough (wife keeps it at 68). I did remove both units and properly clean the coils when I bought the boat. Dirty coils and fans will reduce capacity significantly. It is nearly impossible to properly clean these coils in place if they have been allowed to be packed with dirt and dust. Just brushing the surface will not do it!!!!
Before adding a unit, or changing the ducting, I would make sure the coils are clean, the unit(s) are properly charged and they are working at full capacity.