Welcome to Carver Yachts Owners Forum
We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com
You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!
Generator transfer switch
- Jlubas
- Scurvy Dog
- Posts: 14
- Joined: June 4th, 2017, 8:54 am
- Vessel Info: 1995 Carver 355 Aft Cabin
- Location: Westbrook, CT
- Has thanked: 9 times
Generator transfer switch
The boat is fairly new to me, lost an engine last year on my maiden voyage so it never left the dock. This year started using it and working through this generator problem. What is interesting is I don't have a transfer switch on the panel. This has me super perplexed. I thought maybe there is an automatic transfer somewhere I cant see?
Here is what I am experiencing, if I am on shore power, turn the generator on and switch the breaker pull on the generator to the on position the generator will take over, I can turn the shore power off and the generator will work okay.
If however, I am not on shore power turn the generator on and then flip the breaker pull to the on position it makes a loud buzzing sound on the panel and shuts down.
If I am on or off shore power and I keep the pull in the on position and try to start the generator it will not stay running.
Coming off the generator there are the three normal wires that go into what appears to be a capacitor of some sort first.
My assumption is this is intended to clean the power from the generator before it goes to the panel. I traced the "out" line from the capacitor and it appears to go straight up to the panel.
I reviewed the original schematics and it appears there was an intention for a transfer switch in the panel. There is clearly a spot for it but there is nothing there. I opened up the panel and everything looks extremely neat and organized, like it would have been from the factory. It doesn't appear that anything was changed. All connectors match and there is black starboard where the extra switch opening is.
My assumption is there is some kind of automatic transfer switch somewhere that I cant find. I am also summing that is the cause of the issue. No clue where to go from here. Any suggestions would be GREATLY appreciated!! Thank you.
1995 Carver 355 Aft Cabin
Crusader 454 XLI's
-
- CYO Supporter
- Posts: 2307
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 324 times
- Been thanked: 595 times
Re: Generator transfer switch
- Jlubas
- Scurvy Dog
- Posts: 14
- Joined: June 4th, 2017, 8:54 am
- Vessel Info: 1995 Carver 355 Aft Cabin
- Location: Westbrook, CT
- Has thanked: 9 times
Re: Generator transfer switch
1995 Carver 355 Aft Cabin
Crusader 454 XLI's
-
- CYO Supporter
- Posts: 2307
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 324 times
- Been thanked: 595 times
Re: Generator transfer switch
- jcoll
- Deck Hand
- Posts: 95
- Joined: September 10th, 2014, 12:18 am
- Vessel Info: 1998 355 Motor yacht
- Has thanked: 18 times
- Been thanked: 18 times
Re: Generator transfer switch
- waybomb
- CYO Moderator
- Posts: 2502
- Joined: February 5th, 2013, 9:24 pm
- Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85 - Location: Saint Joseph,Mi
- Has thanked: 53 times
- Been thanked: 426 times
Re: Generator transfer switch
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
- Jlubas
- Scurvy Dog
- Posts: 14
- Joined: June 4th, 2017, 8:54 am
- Vessel Info: 1995 Carver 355 Aft Cabin
- Location: Westbrook, CT
- Has thanked: 9 times
Re: Generator transfer switch
Thank you both very much. So does the boat have an automatic transfer switch or is that what the capacitors and whatever that other thing are doing? It just seems shocking to to me I have no switch. Really appreciate the feedback.
1995 Carver 355 Aft Cabin
Crusader 454 XLI's
- km1125
- Admiral
- Posts: 3500
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 69 times
- Been thanked: 1043 times
Re: Generator transfer switch
The capacitors are part of the automatic switch. The capacitors are to help "lock" the relays so that they don't bounce back and forth between the generator and shore power when there are fluctuations in voltage (such as when a big load like A/C comes on). This is called chatter and will also burn up the points on the relays.
- Jlubas
- Scurvy Dog
- Posts: 14
- Joined: June 4th, 2017, 8:54 am
- Vessel Info: 1995 Carver 355 Aft Cabin
- Location: Westbrook, CT
- Has thanked: 9 times
Re: Generator transfer switch
km1125 wrote:Source of the post You could replace the automatic relays with a manual switch. Start the generator, flip the switch, and you're on generator power. Flip back to shore power when you want.
The capacitors are part of the automatic switch. The capacitors are to help "lock" the relays so that they don't bounce back and forth between the generator and shore power when there are fluctuations in voltage (such as when a big load like A/C comes on). This is called chatter and will also burn up the points on the relays.
Km1125 so do you think that I could be having a problem with the automatic relays? Where are the automatic relays located? I think it is fine to have the automatic relay but I want to make sure that I can get things working appropriately if I need to switch over to a manual switch that is fine, but I can’t seem to locate the automatic relay? Is that the circular piece in the picture that I have above?
1995 Carver 355 Aft Cabin
Crusader 454 XLI's
- km1125
- Admiral
- Posts: 3500
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 69 times
- Been thanked: 1043 times
Re: Generator transfer switch
You either have two double-pole relays, or four single pole relays. These relays ARE the transfer switch (an automatic one) I don't know exactly where they are on your boat, but every time this comes up someone says they are in a box behind the electrical panel. You should be able to follow the wires from that box with the capacitors and see where those wires go.
Be careful working around the AC circuits. Make sure everything is "dead" before you go messing with connections and make sure the capacitors are discharged. As someone pointed out before, the "buzzing" symptom is usually caused by failing capacitors... you might want to get the part numbers off the ones you have and get a couple on order.. they are not very expensive. If you replace the capacitors (and they were the problem), you may never need to find the relays.
Who is online