2001 444 CPMY fresh water system

Discussion of AC's, plumbing and sanitation related issues.
Post Reply
User avatar
Foster15
Scurvy Dog
Scurvy Dog
Posts: 23
Joined: November 14th, 2016, 11:12 am
Vessel Info: 2001 444 cockpit motor yacht
Location: Racine, WI
Been thanked: 1 time

2001 444 CPMY fresh water system

Post by Foster15 »

Hi. New schurflo aqua king II 4 gal per min fresh water pump. Does not provide steady flow; cycles continually (no accumulator tank). Better as more faucets opened. Why am I not getting steady flow? Pump too big?

Other than galley, hot water flow very weak; even on shore water (galley not great). Almost no flow. Faucets have been replaced with home type spout faucets with no aerators. Best flow overall is cold water wet bar faucet (stock) on bridge.

Any thoughts? Appreciate any insights.
Foster 15
444 CMY 2001
Racine, WI
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: 2001 444 CPMY fresh water system

Post by bud37 »

Yea might be a bit big but should work ok, check any valving you might have at the water heater...maybe bypass valves not closed and open properly, and on the pump suction side, there may be a screen between the pump and tank, check that is clean and the valve there is wide open and no restriction at the tank outlet to the pump inlet, one more, check volts at pump..
You could quite simply have a kinked line somewhere, maybe climb around and have a look..thats all I got , good luck man....
FWIW.....The above is just my opinion.
User avatar
RGrew176
Admiral
Admiral
Posts: 6652
Joined: August 17th, 2015, 4:07 am
Vessel Info: 2023 SunTracker Party Barge 22 DLX
Location: Southgate, MI.
Has thanked: 72 times
Been thanked: 470 times

Re: 2001 444 CPMY fresh water system

Post by RGrew176 »

My thinking would be if there is room to add an accumulator tank. It will make a world of difference in how the pump and system work. On my boat I had to replace a seal on my accumulator tank because of a leak. While waiting to fix it I by-passed the accumulator and it was horrible how the system performed.

Much better once I reconnected the accumulator.
Rick Grew

2025 Godfrey Xperience 2286 SFLX

2004 Past Commodore
West River Yacht & Cruising Club
User avatar
g36
Admiral
Admiral
Posts: 2115
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 654 times

Re: 2001 444 CPMY fresh water system

Post by g36 »

this unit doesnt need a accummulator to work properly. what you may have to do is adjust the by-pass and or pressure switch on the front of the new shurflo pump. if you look in your pump manual it will mention which allen screws to adjust and which way yo turn them. pay attention to what direction and how much you turn it so if you mess up you can go back to i ts oem set point. adjusting this will get rid of the low flow and the cycling on the pump. these do work great but out of the box i had to adjust mine some too.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Post Reply