Welcome to Carver Yachts Owners Forum

We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com

You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Generator rebuild

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author United States of America
RaRa
Scurvy Dog
Scurvy Dog
Posts: 13
Joined: April 10th, 2016, 6:34 pm
Vessel Info: 1990 Carver 32 Montego
Location: Kingwood,TX
Has thanked: 18 times
Contact:

Generator rebuild

Postby RaRa » April 6th, 2019, 4:57 pm

Boys and girls, my 32 ft. Montego has a Kohler 6.5 kw generator. Has issues starting and running. Got the guys out, and they say it will be more cost and time efficient to pull that thing out. My bad back concurs with trying to get back down there. The question, solitician of opinions, or whatever, do I go for the new carb, possibly a new starter and cooling system on a 1987 unit? A new unit would be NEW, not old pistons, rings etc?
What say you?
1989 Montego 3257 @ Galveston Yacht Basin

User avatar

Canada
bud37
Admiral
Admiral
Posts: 4865
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 579 times
Been thanked: 1210 times

Re: Generator rebuild

Postby bud37 » April 6th, 2019, 5:16 pm

Well I guess it would hinge on how many hours are on the gen.....you can check, but I believe the marine gennies to be fairly expensive, so a comparison of the costs involved to repair and upgrade as opposed to a brand new one with all the bells and whistles would be warranted here.
The above is strictly my opinion.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5975
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1671 times

Re: Generator rebuild

Postby Viper » April 6th, 2019, 6:24 pm

Have they determined why it's not starting or running right? I wouldn't be removing it until I had a definite answer to that first. Unless access is really bad in your application, what is it that they can't get to without removing the unit, and how much work does it need? is it so much that it can't be done in place?

The old unit are pretty robust and worth rebuilding unless there are major internal issues. I don't know about down your way but up here, a new marine generator of that size if over $10K CAN$. Of course that's only about $1K US$ ;-)

What model you have?
User avatar

United States of America
buster53
Admiral
Admiral
Posts: 1026
Joined: May 12th, 2017, 10:41 am
Vessel Info: 2001, Carver 356
Location: Lower Potomac, VA
Has thanked: 9 times
Been thanked: 261 times

Re: Generator rebuild

Postby buster53 » April 6th, 2019, 9:12 pm

I'll throw this out there FWIW...
I had problems with my Kohler last summer, starting/running and had a tech guy work on it several times and we were baffled. Then one day he just happened to mention that there was a check valve in the fuel line right at or just inside the fuel tank...that's how they were made. Anyway, we put in a new check valve and so far, no issues since.

United States of America
tomschauer
CYO Supporter
CYO Supporter
Posts: 2307
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 324 times
Been thanked: 595 times

Re: Generator rebuild

Postby tomschauer » April 6th, 2019, 9:16 pm

Its more than likely a fuel issue. Gummed up carb, inline filter or failing fuel pump. I personally would try to fix it before spending 7+k for a new one.
User avatar

United States of America
buster53
Admiral
Admiral
Posts: 1026
Joined: May 12th, 2017, 10:41 am
Vessel Info: 2001, Carver 356
Location: Lower Potomac, VA
Has thanked: 9 times
Been thanked: 261 times

Re: Generator rebuild

Postby buster53 » April 6th, 2019, 9:22 pm

tomschauer wrote:Source of the post Its more than likely a fuel issue. Gummed up carb, inline filter or failing fuel pump. I personally would try to fix it before spending 7+k for a new one.


We knew I had a fuel issue as well. Checked the fuel lines, changed filter, new fuel pump, cleaned the carb. That's when the subject of the check valve came up. Replaced it and life is good.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5975
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1671 times

Re: Generator rebuild

Postby Viper » April 6th, 2019, 10:45 pm

buster53 wrote:Source of the post.....check valve in the fuel line right at or just inside the fuel tank....

That would be the anti-siphon valve. They are at the connection port on top of the tank. It's the fitting that the fuel hose hooks up to. They do fail.
User avatar

United States of America
Keith S
Scurvy Dog
Scurvy Dog
Posts: 36
Joined: October 4th, 2017, 6:02 pm
Vessel Info: 2005 38 Super Sport
Location: Oceanport, NJ
Been thanked: 21 times

Re: Generator rebuild

Postby Keith S » April 12th, 2019, 10:41 am

Since Kohler got out of the marine gas generator business, Westerbeke is the only game in town. The prices reflect that and a new generator will cost your 10K+. I would start with a compression test to see what condition your engine is then proceed from there.
User avatar

Topic author United States of America
RaRa
Scurvy Dog
Scurvy Dog
Posts: 13
Joined: April 10th, 2016, 6:34 pm
Vessel Info: 1990 Carver 32 Montego
Location: Kingwood,TX
Has thanked: 18 times
Contact:

Re: Generator rebuild

Postby RaRa » April 27th, 2019, 2:32 pm

Sorry for delay, been in hospital.
Quote for new one is around #12-14k, no labor included. The idea of setting a portable from favorite big boy toy store and use it only out fishing so the Admiral can nap in the cool seems better and better. Run an insulated pipe way above neck with heavy cord below.
The starting issue I’d the carb. Squirt it with start fluid, push button bang! It has now developed a starter issue. I suspect it ls like older cars and the solenoid is stuck. I am just not as able to crawl in when I was 20 on my Ford Galaxy 500!
Ideas?
1989 Montego 3257 @ Galveston Yacht Basin
User avatar

Canada
bud37
Admiral
Admiral
Posts: 4865
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 579 times
Been thanked: 1210 times

Re: Generator rebuild

Postby bud37 » April 27th, 2019, 4:17 pm


Hope you are feeling better.

Considering the estimate, why not pay someone to repair it. The reality is you would have to buy the other one then cords etc.etc..., Running the onboard will be much safer than a portable noise maker on the boat .......they are just unsafe period.

I know , I know, other people run them and are fine, well lots of folk die and get very sick as well. Just my opinion, opinions are cheap I guess..... :-D

Whatever you choose....be safe.
The above is strictly my opinion.

Return to “Electrical”



Who is online

Users browsing this forum: Google [Bot] and 28 guests