Re: Swap out a 12K unit with a 16?
tonyiiiafl wrote:Qr Bbpost I also have a 16 forward and a 12 aft. On a hot summer day they do struggle. Same at night though they are fine. Tough choice here as the replacement cost is really negligible of 12 versus 16.
From the size of your actual cabin space, your 39' is probably the same as my 35'. As with yours, I have the 16k pumping air into the salon and forward berth. My 12k pumps air into the aft cabin and salon. On my boat, the aft cabin cools much quicker than the salon. I'm guessing the same is true for your boat. Anyway, if you do replace your 12 with a 16, I would think you need to somehow cut back the air going into the aft cabin and direct more to the salon, otherwise, the aft cabin will always be much cooler than the salon, maybe too cool. Just a thought.
- tonyiiiafl
- Admiral

- Posts: 902
- Joined: November 19th, 2015, 4:00 am
- Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
- Location: Cape Cod, MA
- Has thanked: 601 times
- Been thanked: 193 times
- km1125
- Admiral

- Posts: 3658
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 81 times
- Been thanked: 1114 times
Re: Swap out a 12K unit with a 16?
If you're return air is pulling from the bilge then you're adding a lot of cooling load on the system. You really want to fix that.
- tonyiiiafl
- Admiral

- Posts: 902
- Joined: November 19th, 2015, 4:00 am
- Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
- Location: Cape Cod, MA
- Has thanked: 601 times
- Been thanked: 193 times
Re: Swap out a 12K unit with a 16?
I have looked at this many times and the blocking off of the bilge air looks like an impossible task. I may take this as a winter project, making a few modifications to reroute that air so it comes mainly from the room return vent. I HAD THOUGHT OF GETTING A PLASTIC BARREL OR TRASH CAN AND CUTTING A SECTION OUT, then placing it over the unit, and then running a duct to th return air vent. It is in design phase now. LOL
- bud37
- Admiral

- Posts: 5182
- Joined: April 23rd, 2015, 10:22 pm
- Has thanked: 604 times
- Been thanked: 1312 times
Re: Swap out a 12K unit with a 16?
tonyiiiafl wrote:Qr Bbpost I have looked at this many times and the blocking off of the bilge air looks like an impossible task. I may take this as a winter project, making a few modifications to reroute that air so it comes mainly from the room return vent. I HAD THOUGHT OF GETTING A PLASTIC BARREL OR TRASH CAN AND CUTTING A SECTION OUT, then placing it over the unit, and then running a duct to th return air vent. It is in design phase now. LOL
Now I have not seen your particular instal but........can you not just attach an insulated duct to the air inlet of the unit itself and run to a filter screen vent in the cabinet side or somewhere where it would just pull cabin air....that seems to be the way ours is.....just a thought.
FWIW.....The above is just my opinion.
- tonyiiiafl
- Admiral

- Posts: 902
- Joined: November 19th, 2015, 4:00 am
- Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
- Location: Cape Cod, MA
- Has thanked: 601 times
- Been thanked: 193 times
Re: Swap out a 12K unit with a 16?
That was my first thought, however, the routing under the aft bed is pretty funky. The air inlet is about 14” square, I need to figure out a way to attach the duct to it, then I may have to oval it out to get to the supply vent, which is a 10” x 14” cut out in the bottom of the aft bed. I am going to see if I can change positions of the unit to make it an easier task to route the duct.
- bud37
- Admiral

- Posts: 5182
- Joined: April 23rd, 2015, 10:22 pm
- Has thanked: 604 times
- Been thanked: 1312 times
Re: Swap out a 12K unit with a 16?
tonyiiiafl wrote:Qr Bbpost That was my first thought, however, the routing under the aft bed is pretty funky. The air inlet is about 14” square, I need to figure out a way to attach the duct to it, then I may have to oval it out to get to the supply vent, which is a 10” x 14” cut out in the bottom of the aft bed. I am going to see if I can change positions of the unit to make it an easier task to route the duct.
You just need some transitions.......people that do home furnace/air ductwork can make them so they flow correctly to go from your 14" square to whatever you need.....or at least tell you what sizes you need to make...
FWIW.....The above is just my opinion.
- tonyiiiafl
- Admiral

- Posts: 902
- Joined: November 19th, 2015, 4:00 am
- Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
- Location: Cape Cod, MA
- Has thanked: 601 times
- Been thanked: 193 times
Re: Swap out a 12K unit with a 16?
Transitions would be hard pressed to get attached to the air intake of the condenser. That is why I thought of building a box around it with a removable cover. Then putting a transition on one side to pull the air in from the inside vent with a duct. Attached is a photo of the unit.
You do not have the required permissions to view the files attached to this post.
- bud37
- Admiral

- Posts: 5182
- Joined: April 23rd, 2015, 10:22 pm
- Has thanked: 604 times
- Been thanked: 1312 times
Re: Swap out a 12K unit with a 16?
Yup I see your problem....I think you could still do it, would just take a while to fab a box in front of the coil section....do they have a retrofit piece for your unit maybe??.......actually this is what I initially thought you may have got, one more like this.
You do not have the required permissions to view the files attached to this post.
FWIW.....The above is just my opinion.