generator
- A Lee
- Scurvy Dog

- Posts: 25
- Joined: April 1st, 2018, 9:53 am
- Vessel Info: 2005 56' Voyger
- Location: Mississippi
- Been thanked: 3 times
generator
Kohler diesel generator shuts down with fault code RF. I replaced primary and secondary fuel filters guessing RF stands for replace filter? That has not solved the problem. I cant find RF code and what is means-
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
- vineyardgray
- Captain

- Posts: 262
- Joined: July 15th, 2018, 10:26 pm
- Has thanked: 128 times
- Been thanked: 33 times
- Contact:
- Marty
- Deck Hand

- Posts: 95
- Joined: November 17th, 2017, 8:02 pm
- Vessel Info: 2000 326 AFT Cabin
- Location: Georgian Bay
- Has thanked: 16 times
- Been thanked: 9 times
Re: generator
I agree check the water flow first....if flow is restricted check your strainers, impeller and possible even your intake hose from the scupper. I pulled an entire salad out of my intake hose a couple weeks ago....
- A Lee
- Scurvy Dog

- Posts: 25
- Joined: April 1st, 2018, 9:53 am
- Vessel Info: 2005 56' Voyger
- Location: Mississippi
- Been thanked: 3 times
Re: generator
Thank you for the responses. After further investigation and confirming the fireboy system was not causing the issue, the main circuit board in the generator was faulty. I was informed that you can get erroneous codes when circuit board is failing.