I've been chasing an issue with water in my bilge that seems to point to my a/c units. In troubleshooting this problem I decided to verify the purpose of all of my above-waterline thru hull fittings (fittings shown in owners manual don't match actual). When I run my a/c units (separately), all three discharge water through the same three fittings. The three locations are port side forward, port side aft, and starboard side aft. Additionally, my aft shower sump also discharges through the same starboard location.

Hoping there's someone with a theory on how this can be.
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: 396 a/c discharge problem?

Post by Midnightsun »

I do not think that would be possible. Reason I say this is, you would need in-line check valves and the danger of sinking the boat if a check valve would fail is very likely. I say check again, you must have seen wrong.

As for the AC condensate, this should run into the shower sump and get pumped overboard when the float activates the pump. I have a feeling the problem lies there as this is a rather problematic area. The shower sump should be cleaned out annually at least, not just a peek in the box and call it a day.

Welcome to the forum by the way.
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
User avatar
paulmadore
Scurvy Dog
Scurvy Dog
Posts: 4
Joined: February 17th, 2019, 5:13 pm
Vessel Info: 2000 Carver 396
Cummins Diesel Engines
Location: Midland Ontario
Has thanked: 3 times

Re: 396 a/c discharge problem?

Post by paulmadore »

Thanks Hans. I've sorted out the sump and it's not going out where I thought. I'm going to keep chasing the a/c discharge.
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: 396 a/c discharge problem?

Post by bud37 »

paulmadore wrote:Qr Bbpost I've been chasing an issue with water in my bilge that seems to point to my a/c units. In troubleshooting this problem I decided to verify the purpose of all of my above-waterline thru hull fittings (fittings shown in owners manual don't match actual). When I run my a/c units (separately), all three discharge water through the same three fittings. The three locations are port side forward, port side aft, and starboard side aft. Additionally, my aft shower sump also discharges through the same starboard location.

Hoping there's someone with a theory on how this can be.


Welcome to the forum......have a real good look where the ac unit condensate drains go.....in our boat it goes out it's own thru hull but this boat only has one unit.......could just be a hose has a split from the winter or a loose clamp/ fitting.

All three of those units will use the one common raw water cooling pump, is my guess.
FWIW.....The above is just my opinion.
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: 396 a/c discharge problem?

Post by bud37 »

I looked at your boats parts schematics and it show on there the condensate drains are split between the forward sump and the aft sump.
FWIW.....The above is just my opinion.
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: 396 a/c discharge problem?

Post by Midnightsun »

bud37 wrote:Qr Bbpost I looked at your boats parts schematics and it show on there the condensate drains are split between the forward sump and the aft sump.


Thats like mine, the main and aft cabin AC condensates run into the aft shower sump and the forward AC condensate runs into the forward shower sump.

Just so there is no confusion. The condensate is just that, dripping water from the AC that ends up in the AC pan and then gets directed overboard, a shower sump or sometimes just into the bilge. Then there is the AC circulation pump which draws water from the lake/ocean and runs it through the AC and then back out again. In a multi AC configuration this is normally 1 pump supplying water to all units.
Last edited by Midnightsun on July 7th, 2020, 2:53 pm, edited 1 time in total.
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
User avatar
paulmadore
Scurvy Dog
Scurvy Dog
Posts: 4
Joined: February 17th, 2019, 5:13 pm
Vessel Info: 2000 Carver 396
Cummins Diesel Engines
Location: Midland Ontario
Has thanked: 3 times

Re: 396 a/c discharge problem?

Post by paulmadore »

I have one pump that feeds all three units through a manifold (I'd attach a photo of my technical skills permitted). Is it possible that when one ac unit comes on and calls for water, I have water going through all three whether they are turned on or not? This would explain water discharge through all three hull fittings regardless which unit is turned on.
User avatar
paulmadore
Scurvy Dog
Scurvy Dog
Posts: 4
Joined: February 17th, 2019, 5:13 pm
Vessel Info: 2000 Carver 396
Cummins Diesel Engines
Location: Midland Ontario
Has thanked: 3 times

Re: 396 a/c discharge problem?

Post by paulmadore »

My condensates are plumbed as you have indicated.
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: 396 a/c discharge problem?

Post by Midnightsun »

paulmadore wrote:Qr Bbpost I have one pump that feeds all three units through a manifold (I'd attach a photo of my technical skills permitted). Is it possible that when one ac unit comes on and calls for water, I have water going through all three whether they are turned on or not? This would explain water discharge through all three hull fittings regardless which unit is turned on.


Yep, this is how it works.
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
User avatar
mjk1040
Admiral
Admiral
Posts: 1531
Joined: July 30th, 2015, 8:15 am
Vessel Info: 1998 355 AC/MY "Deja Vu"
Location: Savannah, NY
Has thanked: 9 times
Been thanked: 248 times

Re: 396 a/c discharge problem?

Post by mjk1040 »

The AC drip pan drains could very well be plugged. I just disconnect mine at the shower sump and sucked them out with the shop vac. Pan was over flowing into the bilge. If you bilge water looks clean, your hot water tank relief valve or drain valve could be leaking and that drains into the bilge.
Mike :down: