Potable Water Pump Continuously Running
- Marty
- Deck Hand

- Posts: 95
- Joined: November 17th, 2017, 8:02 pm
- Vessel Info: 2000 326 AFT Cabin
- Location: Georgian Bay
- Has thanked: 16 times
- Been thanked: 9 times
Re: Potable Water Pump Continuously Running
Yeah the current pump is a SHURFLO 39010216 - 12V, 7.5A 55 PSI, 5 AMP Max and 3 GPM - ignition protected- Replacement is 4138-111-E65 for around $200 best I can find on Amazon.
- Marty
- Deck Hand

- Posts: 95
- Joined: November 17th, 2017, 8:02 pm
- Vessel Info: 2000 326 AFT Cabin
- Location: Georgian Bay
- Has thanked: 16 times
- Been thanked: 9 times
Re: Potable Water Pump Continuously Running
Back up at the boat and found a small drip at the intake for the pump at the FPT connector. Will swap that out and hopefully it will correct the cycling of the pump continuously
- Marty
- Deck Hand

- Posts: 95
- Joined: November 17th, 2017, 8:02 pm
- Vessel Info: 2000 326 AFT Cabin
- Location: Georgian Bay
- Has thanked: 16 times
- Been thanked: 9 times
Re: Potable Water Pump Continuously Running
Changed a couple fittings as there was evidence of a small leak, but did not fix the issue. Ended up replacing the pump and that was the issue. Original pump so it was 20+ years old.
- km1125
- Admiral

- Posts: 3658
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 81 times
- Been thanked: 1114 times
Re: Potable Water Pump Continuously Running
If you're curious, take the old pump apart. You'll probably find some "gunk" on the valves and you can clean them and put it together and it'll probably work fine again... and you can keep it as a spare.
- Marty
- Deck Hand

- Posts: 95
- Joined: November 17th, 2017, 8:02 pm
- Vessel Info: 2000 326 AFT Cabin
- Location: Georgian Bay
- Has thanked: 16 times
- Been thanked: 9 times
Re: Potable Water Pump Continuously Running
Thanks for the advice KM1125. Looks like I will have a decent spare. Opened the pump up and there was a piece of plastic stuck in it. Based on how/where the pump was mounted it was impossible to work on so remove and replace was the best option.
You do not have the required permissions to view the files attached to this post.
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
- km1125
- Admiral

- Posts: 3658
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 81 times
- Been thanked: 1114 times
Re: Potable Water Pump Continuously Running
I'm glad to hear you got it fixed. Even if you didn't though, I think it's pretty fun finding out what actually happened that caused something to stop working.
You might find a lot of other uses for it too... like a portable wash-down pump or a boat sprinkler to get the little kids wet!!
You might find a lot of other uses for it too... like a portable wash-down pump or a boat sprinkler to get the little kids wet!!