1990 3608 aft cabin freshwater pump location

Anything related to the operation of your boat. Steering, Bilge Pumps, thru-hulls, bottom paint, etc.
Post Reply
User avatar
Take5
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: June 5th, 2020, 9:21 pm
Vessel Info: 1990 3608
Location: Maryland

1990 3608 aft cabin freshwater pump location

Post by Take5 »

My water pressure seems low. The stream of water will start off ok but then get weak. Doesn’t change when hooked up to dock water. Trying to locate where the pump is so I can investigate. Thanks
User avatar
waybomb
CYO Moderator
CYO Moderator
Posts: 2747
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 69 times
Been thanked: 492 times

Re: 1990 3608 aft cabin freshwater pump location

Post by waybomb »

Dock water does not go through the pump.
When connected to city water you should have city pressure.
Filter clogged?
Bad pressure reducer?
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
User avatar
Take5
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: June 5th, 2020, 9:21 pm
Vessel Info: 1990 3608
Location: Maryland

Re: 1990 3608 aft cabin freshwater pump location

Post by Take5 »

That is good to know . I will check my reducer and filter. Thank you!
User avatar
buster53
Admiral
Admiral
Posts: 1170
Joined: May 12th, 2017, 10:41 am
Vessel Info: 2001, Carver 356
Location: Gwynn’s Island, VA
Has thanked: 10 times
Been thanked: 285 times

Re: 1990 3608 aft cabin freshwater pump location

Post by buster53 »

FWIW, on my 3807, the water pump could be accessed by a very small opening underneath the steps going down to the galley.
If not there, turnoff the dock water, turn on your water system and follow the sound of the pump.

Agree with others, sounds like a partially clogged filter
User avatar
g36
Admiral
Admiral
Posts: 2115
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 654 times

Re: 1990 3608 aft cabin freshwater pump location

Post by g36 »

Pump should be close proximity to the boats water tank. My aft csbin water tank is under aft mattress have you checked in that area?
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
User avatar
km1125
Admiral
Admiral
Posts: 3658
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 1990 3608 aft cabin freshwater pump location

Post by km1125 »

Not sure on the 3608s, but on the 3607s the fresh water pump is under the bottom of the port side cabinetry right next to the aft berth. There's a hinged hatch that swings up to allow access once you open the cabinet door.
User avatar
Take5
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: June 5th, 2020, 9:21 pm
Vessel Info: 1990 3608
Location: Maryland

Re: 1990 3608 aft cabin freshwater pump location

Post by Take5 »

Update. I get no water when hooked up to the dock. With the water pump on I get very weak cold water and none from the hot side. I just recently got this boat so I am unfamiliar with how the system works. Any suggestions would be greatly appreciated.
User avatar
denpooch
Commander
Commander
Posts: 386
Joined: April 9th, 2017, 8:03 pm
Vessel Info: 2005 360 Mariner
Crusader 6.0 Captains Choice
Location: Long Island
Has thanked: 85 times
Been thanked: 89 times

Re: 1990 3608 aft cabin freshwater pump location

Post by denpooch »

When you are hooked up to water on the dock, you 'turn off' the breaker for onboard water pump. The dock hose inlet will bypass the pump and deliver the water directly to the system. If you are not getting any water from the dock, this might be an indication of a faulty valve that will prevent the water from flowing 'out' of the city water inlet when using the pump. I believe that this I called a 'check valve'.
This diagram seems to explain the system. I do not have an 'accumulator tank' in my system.

https://newcontent.westmarine.com/conte ... ater-4.jpg
User avatar
km1125
Admiral
Admiral
Posts: 3658
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 1990 3608 aft cabin freshwater pump location

Post by km1125 »

You might have to do a thorough inspection of the whole water system. A previous owner might have installed valves to bypass for winterizing.

Also check the individual faucets. There are usually screens in the aerators that could be getting clogged up not allowing flow. That's really the only common point to either the shore water or the on-board pump. Often the on-board pump runs at a higher pressure than the shore water so that might explain why you see a trickle when it's on.