Generator Diesel Fuel Shut Off Valve

Anything related to the operation of your boat. Steering, Bilge Pumps, thru-hulls, bottom paint, etc.
Post Reply
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Generator Diesel Fuel Shut Off Valve

Post by Midnightsun »

Changed my generator filter last week. Found out it has no shutoff valve so I used a vice grip to squeeze the feed line shut while I replaced the filter. Worked fine but figured I should make this right by installing a small 3/8" ball valve since the line is marked as 3/8". Will install close to filter for easy access in the future.

Question, is there any need for something special for a valve? I assume this is fine with a couple of good hose clamps on each end?
https://www.amazon.ca/Litorange-Switch- ... 3572&psc=1
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Generator Diesel Fuel Shut Off Valve

Post by Viper »

You're fine with clamps. You shouldn't pinch newer A1+ fuel lines anymore. You can ruin the inner plastic lining that was introduced in recent years to minimize permeation and deal with ethanol fuels.
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Generator Diesel Fuel Shut Off Valve

Post by Viper »

Hans, get yourself an Oetiker clamp kit. It's perfect for that sort of thing. They're not as easy to remove as they must be cut but it's quick and they won't strip like the screw type will especially on that size clamp. Make sure it's a stainless steel clamp version and look for a kit with the tool, they usually have several size clamps included.
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: Generator Diesel Fuel Shut Off Valve

Post by Midnightsun »

Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
User avatar
AndiamoSeattle
Scurvy Dog
Scurvy Dog
Posts: 11
Joined: February 24th, 2018, 7:47 pm
Vessel Info: 2006, Carver 4137 CMY, Originally commissioned in 2008, it has spent its last 10 years in the Puget Sound, WA. She features the Volvo-Penta D6, 310 diesel motors (485hr.), 3 zone AC/ Heat pumps, fresh water wash down in bow, bow and stern thruster, 8.0KW Kohler generator, 2/ 30amp shore power input from either mid-ship or stern plugins. Bridge refrigerator ice maker, electric galley featuring an electric oven.
Location: Seattle, WA
Has thanked: 50 times
Been thanked: 2 times

Re: Generator Diesel Fuel Shut Off Valve

Post by AndiamoSeattle »

Midnightsun, I too found no shut-off valve on my 41CMY and made quite the mess with spilled diesel. I will heed your advice and install a ball valve! Thanks
Post Reply