Re: Main salon battery switch access under steps
Unless the generator battery is somehow connected to the other banks, that shouldn't be the problem. Generator batteries are usually isolated from everything else, in other words you can't select it as a bank to run your engines or house systems, so that wouldn't be the one you're noticing to be losing it's charge and it's separate charger shouldn't be the issue.
- km1125
- Admiral

- Posts: 3657
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 81 times
- Been thanked: 1114 times
Re: Main salon battery switch access under steps
Touch each alternator when the engines are cooled down and see if one is warmer than the other. It's not very common, but you can have a failed diode (recifier) inside the alternator that will cause a drain whenever the engine is connected to the battery.
- Phrancus
- Commander

- Posts: 395
- Joined: October 1st, 2020, 10:03 am
- Vessel Info: Sold: Carver 26 Command Bridge / 280 sedan 1992.
- Location: Netherlands, Europe
- Has thanked: 16 times
- Been thanked: 136 times
- Contact:
Re: Main salon battery switch access under steps
5.8 amps of draw.
that's a lot. Not a simple light or standby device. Lot's of good suggestions above. I might add: perhaps there is a device connected in a wrong way. Either on purpose like a bilge pump that has a connection through the breaker panel and one around it for continuous standby. Or by mistake when a connection was made in a way that current flows when a plus becomes a relative minus. Or through a damaged wire that does not cause trouble when all is powered with enough amperage to allow for the leaking but does when the supply is gone.
My advice: disconnect all, reconnect one by one. Start with the generator as suggested above, if that provides the source. go on and check the rest one by one anyway as this will help you in the future.
Share your Carver experiences, share marine life. Donate when you can but post what your Carver adds to your life too!
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times
Re: Main salon battery switch access under steps
I personally would start with that Zantrex charger / inverter. They had a really high failure rate.
I would disconnect it totally and see if your drain doesn't disappear.
I would disconnect it totally and see if your drain doesn't disappear.