1994 390CPMY 11 gallon water heater

Discussion of AC's, plumbing and sanitation related issues.
User avatar
km1125
Admiral
Admiral
Posts: 3657
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 1994 390CPMY 11 gallon water heater

Post by km1125 »

On mine there wasn't a visible thermostat, but if you removed the cover the temperature control device was adjustable.
User avatar
tonyiiiafl
Admiral
Admiral
Posts: 902
Joined: November 19th, 2015, 4:00 am
Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
Location: Cape Cod, MA
Has thanked: 601 times
Been thanked: 193 times

Re: 1994 390CPMY 11 gallon water heater

Post by tonyiiiafl »

I did remove my cover where the wires go in. No stat here.
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: 1994 390CPMY 11 gallon water heater

Post by Viper »

The thermostat is a set thermal type round switch. Their high limit switches were round and usually had a little red reset button on them. There must be a stat and limit switch.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: 1994 390CPMY 11 gallon water heater

Post by tomschauer »

Thermostat and high limit cut out are on the front of the unit where your 120v wiring enters. The stock units are not adjustable.
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: 1994 390CPMY 11 gallon water heater

Post by Viper »

Tom is correct. Your hot AC wire will be going through the stat and limit switch before heading on to the heating element.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: 1994 390CPMY 11 gallon water heater

Post by tomschauer »

You have a klixon thermostat and and a klixon resettable high limit switch. At least you should.
These are round, about the diameter of a quarter. The high limit should have a very small red stem for resetting.
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: 1994 390CPMY 11 gallon water heater

Post by bud37 »

All water heaters should have a safety circuit of some sort with a high limit and temp control or there can be catastrophic results ( can explode) if the heat stays on and the relief valve fails.Try to find yours and determine if it works correctly.
FWIW.....The above is just my opinion.
User avatar
tonyiiiafl
Admiral
Admiral
Posts: 902
Joined: November 19th, 2015, 4:00 am
Vessel Info: 1994 Carver 39 Cockpit Motor Yacht
Location: Cape Cod, MA
Has thanked: 601 times
Been thanked: 193 times

Re: 1994 390CPMY 11 gallon water heater

Post by tonyiiiafl »

[quote][/quote]

Mine DOES turn on and turn off, just nothing I saw under that cover. Going to dig in again.
Post Reply