Shower sump
- jsurfwhite
- Scurvy Dog

- Posts: 28
- Joined: June 15th, 2020, 4:12 pm
- Vessel Info: 2000 Carver 356 Aft Deck
- Location: Florida
- Has thanked: 12 times
- Been thanked: 4 times
Shower sump
My forward shower sump has failed on my 2000 356 Aft Cabin. What are recommendations on replacement? I see an Atwood sump box on Amazon that may work. Thanks
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: Shower sump
Whats meant by failed? Float switch ? or you could take the pump out and check the bottom of it for hair etc that can get wrapped around the shaft. You could just replace the switch or pump that's in the sump now . Good chance it's a small rule pump.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- jsurfwhite
- Scurvy Dog

- Posts: 28
- Joined: June 15th, 2020, 4:12 pm
- Vessel Info: 2000 Carver 356 Aft Deck
- Location: Florida
- Has thanked: 12 times
- Been thanked: 4 times
Re: Shower sump
Pump is not coming on. Could be pump or switch. I have not investigated failure mode yet. One of my boating associates recommended a full sump replacement.
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: Shower sump
I would then check for sump breaker tripped. If it is Then pull pump and check for hair at bottom of pump this can cause pump breaker to trip. And test float if not pump.. my sump breakers are under step coming in from sun deck not sure if yours on 356 is same.. You can replace the whole box but save some money and replace only whats needed. Imo.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- Cooler
- Admiral

- Posts: 1685
- Joined: May 22nd, 2018, 12:09 pm
- Vessel Info: 1995 Carver 330 Mariner
Twin 350XL Crusaders
Home port: Menominee, MI - Location: Green Bay, WI
- Has thanked: 68 times
- Been thanked: 414 times
Re: Shower sump
I would think it is just the float switch. You can test by bypassing the switch. If it is the float switch, make sure you replace with a low profile type like the flat Attwood. Needs to stay under the screen and still get to on position. $40 instead of $200, and much easier to replace.
er
Cooler By The Lake
( All weather people have to say this on air, near lakes )
( All weather people have to say this on air, near lakes )
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: Shower sump
I only posted about hair on the pump throwing breaker because I have had this happen to me and I sure never thought about it being the problem. Either thing pump or float should be a easy fix
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- Rob Lynch
- Scurvy Dog

- Posts: 1
- Joined: July 1st, 2021, 1:02 pm
- Vessel Info: 1996 carver 440 my / 1125 hrs / twin Cummins 6ct8 turbo
- Location: Georgian Bay, ON
Re: Shower sump
Just had this issue last week on our 440. Older floats relied on a mercury ball which is likely the issue. Cut the electrical feed wires and touch together. This should activate the pump confirming your float requires replacement. Inexpensive (50) and no more than 30 mins to complete