Are you on the Great Lakes or Florida coast? I assume you have 3 units on that boat and if so, I think the salon unit is 12k.
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: AC size
My 405 aft cabin has 16000 in salon
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- buster53
- Admiral

- Posts: 1170
- Joined: May 12th, 2017, 10:41 am
- Vessel Info: 2001, Carver 356
- Location: Gwynn’s Island, VA
- Has thanked: 10 times
- Been thanked: 285 times
Re: AC size
OP didn’t say, but sounds like he has a 3807. I used to have a 3807 and if I recall, the salon was 12k.
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: AC size
I think their cu ft interior spaces of the 2 boats is pretty similar (just googling)but I do know with all the windows there's a lot of thermal transfer on both which ever he has ... I know I would not want any smaller, maybe even larger down here in Tennessee . 
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- Midnightsun
- CYO Supporter

- Posts: 2984
- Joined: March 27th, 2016, 2:27 pm
- Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's - Location: Montreal, Canada
- Has thanked: 272 times
- Been thanked: 1193 times
Re: AC size
For what it's worth, mine came with a 16,000 btu for the salon and there is an 11,000 in the forward cabin that also partially supplies the salon. Point is the salon needs quite a bit to keep up. That being said I would definitely go with a 16,000 btu.
- buster53
- Admiral

- Posts: 1170
- Joined: May 12th, 2017, 10:41 am
- Vessel Info: 2001, Carver 356
- Location: Gwynn’s Island, VA
- Has thanked: 10 times
- Been thanked: 285 times
Re: AC size
You have to be careful with sizing and electric draw. When we had all 3 AC units running on our 3807, we were pulling 29 amps. If we had replaced just one of those units with one another size larger, we would have exceeded the 30 amp limit, meaning we would only be able to run 2 units, not all 3.
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: AC size
I would have thought a 3807 would have had 50 amp 120 service x2 like my 405 does instead of only 30 amp. Newer units would probably more energy efficient which will help too.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- Midnightsun
- CYO Supporter

- Posts: 2984
- Joined: March 27th, 2016, 2:27 pm
- Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's - Location: Montreal, Canada
- Has thanked: 272 times
- Been thanked: 1193 times
Re: AC size
Or at the least dual 30's. Usually as soon as AC is added as an option they kick in an additional 30a inlet and in the case of multiple AC units dual 50a 110 or single 50a 220 is the norm.
- buster53
- Admiral

- Posts: 1170
- Joined: May 12th, 2017, 10:41 am
- Vessel Info: 2001, Carver 356
- Location: Gwynn’s Island, VA
- Has thanked: 10 times
- Been thanked: 285 times
Re: AC size
Yes, my 3807 did come from the factory with dual 50 amp, 120 volt service, however, when was the last time you saw a marina that offered 120-50 amp? I never have. Previous owner had special shore power cords made up…male 120-30 amp with female 120-50 amp. That way, the boat could be plugged in at any marina as all offer 120-30.g36 wrote:I would have thought a 3807 would have had 50 amp 120 service x2 like my 405 does instead of only 30 amp. Newer units would probably more energy efficient which will help too.
One cord powered all 3 AC units, other cord powered everything else.