AC overheats flips breaker on AC unit (3807)

Discussion of AC's, plumbing and sanitation related issues.
Post Reply
User avatar
justtls
Scurvy Dog
Scurvy Dog
Posts: 14
Joined: January 12th, 2015, 1:18 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Has thanked: 6 times

AC overheats flips breaker on AC unit (3807)

Post by justtls »

Greetings all and thanks for taking the time to read this. I finally got all three of the AC units to run correctly. Unfortunately the unit in the back stateroom runs for about 15 to 20 minutes before it overheats and flips the breaker on the AC pump itself. All 3 AC units get water from a central water pump and discharge through separate areas so I dont think its the intake, could it be low on freon? Can that cause a unit to overheat. Thanks again for your help.

Regards,
TLS
User avatar
waybomb
CYO Moderator
CYO Moderator
Posts: 2745
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 69 times
Been thanked: 492 times

Re: AC overheats flips breaker on AC unit (3807)

Post by waybomb »

How is the flow from its water discharge? May have a semi-clogged heat exchanger? I know somebody sells something you can flush the lines with, but the name escapes me.
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: AC overheats flips breaker on AC unit (3807)

Post by Viper »

Are you sure the the breaker tripping is the result of something on the unit overheating? What is exactly is overheating?
User avatar
Lyndon670
Admiral
Admiral
Posts: 657
Joined: July 29th, 2013, 11:35 pm
Vessel Info: 2000 Carver 506
Volvo TAMD74EDC
Location: Georgian Bay
Has thanked: 124 times
Been thanked: 140 times

AC overheats flips breaker on AC unit (3807)

Post by Lyndon670 »

I had a similar issue on my 93 Silverton. AC would run for 30 min and then breaker would shut off. After much investigation it turned out that the breaker was weak. I replaced the breaker with the identical new one and it is still running strong with the new owners.
Lyndon,
2000 Carver 506
FOXY JOE
Volvo 7.4TAMD
Queens Cove Marina
Georgian Bay, Ontario