Kohler generator

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar
wsteelenyc
Scurvy Dog
Scurvy Dog
Posts: 1
Joined: September 30th, 2022, 11:09 am
Vessel Info: 1993 CARVER 350 ACMY Aft Cabin
Location: New York, NY

Re: Kohler generator

Post by wsteelenyc »

Anyone have any thoughts in why this worked with my Kohler generator? I'm assuming it had a similar result as flashing the field, but not sure.
https://youtu.be/gTjASKf8HLE
User avatar
KyleR
Commander
Commander
Posts: 363
Joined: July 8th, 2022, 10:50 am
Vessel Info: MV Verity
2002 Carver 396
Twin Cummins 6BTA 370HP
Location: On the move!
Has thanked: 153 times
Been thanked: 149 times

Re: Kohler generator

Post by KyleR »

Never seen that before, but I will say that corrosion on connections does some really weird things! Whenever I see something unusual in my electrical system, unless it is something obvious, my first go-to is to look for corroded connections. I have found ones that looked like they were okay end up being the culprit! I would definitely want to figure that one out though! :-O I generally take the KISS approach until proven otherwise. :-D
MV Verity
2002 Carver 396
Twin Cummins 6BTA 370HP
User avatar
km1125
Admiral
Admiral
Posts: 3657
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: Kohler generator

Post by km1125 »

Yep, same as flashing the field, but it's using the loads as a temporary source.

This is the same reason most (if not all) generators have a capacitor. The capacitor stores a bit of energy and feeds it back to the generator for it to develop that magnetic field. If the capacitor is bad, then you can feed any energy into the generator to get it to develop one. That's why some folks will use an old drill motor and spin it while plugged into the generator... the drill motor is acting as a micro generator and gives just enough voltage so that the big generator will develop a magnetic field.

That guy likely has a capacitor that's failed or failing.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: Kohler generator

Post by tomschauer »

Yep, the capacitor has failed.
Post Reply