You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Genset running out of fuel

GAS engine, transmission and generator repair and maintenance discussion forum.
User avatar

Canada
bud37
Admiral
Admiral
Posts: 4850
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 575 times
Been thanked: 1202 times

Re: Genset running out of fuel

Postby bud37 » June 18th, 2024, 4:36 pm

Does the generator act the same way when the main engines are off ?

If so shut off the fuel to engines valving ( isolate the mains ) while running the gen and see if the same thing occurs.
The above is strictly my opinion.

User avatar

Topic author Canada
MyPleasure
First Mate
First Mate
Posts: 106
Joined: October 18th, 2022, 7:08 pm
Vessel Info: 1992 Carver 36 aft cabin with Volvo 740b engines. Westerbeke 5kw generator. Bought the boat in Portland Oregon in June, and a friend and I brought it up to Sidney, BC. Great trip!
Location: Victoria
Has thanked: 2 times
Been thanked: 18 times

Re: Genset running out of fuel

Postby MyPleasure » June 18th, 2024, 5:19 pm

Hi Bud37. I haven’t run the mains for long enough to see if I the generator quits while they are running. I have for a short time, like maybe 3-4 minutes to see if it will help draw fuel to the generator, but that didn’t seem to make a difference.
I know that the generator fuel pump is working properly, it just seems to run out of fuel after 10-20 minutes. Like I said earlier, I’ll check the current valve to make sure that there is no leak, and if that doesn’t seem to be working properly, I’ll install a new switch.
Al
1st Carver 1987 32 Aft Cabin
2nd Carver 1989 4207 Aft Cabin
3rd Carver 1995 350 Voyager
4th (current) 1992 36 Carver Aft Cabin
User avatar

Canada
bud37
Admiral
Admiral
Posts: 4850
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 575 times
Been thanked: 1202 times

Re: Genset running out of fuel

Postby bud37 » June 18th, 2024, 6:17 pm

Imo...the mains will not help to pull fuel for the gen, they will compete with it for supply depending on how you have the valves configured. Consider vapor lock from increase in suction pressure if all mechanical fittings end up being in top shape, lets see first though with the valve check.

Good idea checking for air infiltration. It is still good practice to have the gen on its own fuel supply lines from its own tank pickups though.....good luck hopefully it is something real simple..... :down:
The above is strictly my opinion.
User avatar

United States of America
km1125
Admiral
Admiral
Posts: 3484
Joined: February 28th, 2017, 6:04 pm
Has thanked: 69 times
Been thanked: 1031 times

Re: Genset running out of fuel

Postby km1125 » June 19th, 2024, 10:28 am

Not sure I'd like that additional "complication" of having the genset T'd into the main engine fuel lines.
User avatar

Topic author Canada
MyPleasure
First Mate
First Mate
Posts: 106
Joined: October 18th, 2022, 7:08 pm
Vessel Info: 1992 Carver 36 aft cabin with Volvo 740b engines. Westerbeke 5kw generator. Bought the boat in Portland Oregon in June, and a friend and I brought it up to Sidney, BC. Great trip!
Location: Victoria
Has thanked: 2 times
Been thanked: 18 times

Re: Genset running out of fuel

Postby MyPleasure » June 19th, 2024, 12:16 pm

Not much that I can do about the fuel line, as far as I can tell, it came this way from the factory. If the generator was added aftermarket, I could see them installing the fuel lines this way rather than having to remove the fuel tanks to install a separate fuel supply for the generator.There is definitely no room to install a separate fuel tank for the generator.
I never checked how the generator on our 4207 got its fuel, but I know that it did draw its fuel from the port tank. Being diesel, it was great to have the fuel transfer pump to help level the boat out after using the generator. But I never had much for solar power back then, so the generator was used a lot more.
I would like to hear from other owners of this model with gas engines to hear how their generator fuel lines are installed? I think this model is a 1992 3608, I believe that they were built from 1990 - 1995, then they extended the swim platform and called it a 405 - 406.
Al
1st Carver 1987 32 Aft Cabin
2nd Carver 1989 4207 Aft Cabin
3rd Carver 1995 350 Voyager
4th (current) 1992 36 Carver Aft Cabin
User avatar

United States of America
ColRon
Admiral
Admiral
Posts: 563
Joined: April 24th, 2017, 6:06 pm
Vessel Info: 1989 Carver Santego 3867
“Escape Plan”
Location: Murray, KY
Has thanked: 77 times
Been thanked: 153 times

Re: Genset running out of fuel

Postby ColRon » June 21st, 2024, 4:58 pm

Are you sure it’s a fuel problem? I say this because last year my gas genny would run about half an hour or so and then shut down. I thought I was having a fuel issues, because after it sat a while (20 min or so) it would fire back without a problem. I finally figured out that it was over heating. And while the impeller had been replaced and it was pumping water, it wasn’t pumping enough due to a blockage from bits of previous impellers. After a good cleaning and flushing of the raw water cooling, it no longer overheating and my shutdown issue has disappeared.
Ron
1989 Carver Santego 3867
“Escape Plan”
Murray, KY

:usa:
User avatar

United States of America
KyleR
CYO Supporter
CYO Supporter
Posts: 268
Joined: July 8th, 2022, 10:50 am
Vessel Info: MV Verity
2002 Carver 396
Twin Cummins 6BTA 370HP
Location: On the move!
Has thanked: 113 times
Been thanked: 111 times

Re: Genset running out of fuel

Postby KyleR » June 22nd, 2024, 9:52 am

I finally figured out that it was over heating. And while the impeller had been replaced and it was pumping water, it wasn’t pumping enough due to a blockage from bits of previous impellers.


Similar thing happened with ours - but it turned out that the intake strainer (the exterior one on the hull) had been painted over multiple times and was clogged. Luckily I figured it out and was able to thoroughly clean it out during a short-haulout to swap props. Ran perfectly after that.

Good luck and please keep us posted when you find your solution! :captain2:
MV Verity
2002 Carver 396
Twin Cummins 6BTA 370HP
User avatar

Topic author Canada
MyPleasure
First Mate
First Mate
Posts: 106
Joined: October 18th, 2022, 7:08 pm
Vessel Info: 1992 Carver 36 aft cabin with Volvo 740b engines. Westerbeke 5kw generator. Bought the boat in Portland Oregon in June, and a friend and I brought it up to Sidney, BC. Great trip!
Location: Victoria
Has thanked: 2 times
Been thanked: 18 times

Re: Genset running out of fuel

Postby MyPleasure » June 22nd, 2024, 4:26 pm

Thanks fellas. There is definitely no problem with the cooling, I put a full port ball valve just above the thru hull, and it pumps an amazing amount of water! Funny though, none of my previous Carvers, also our present one, never had strainers over the intakes for the generators. I just installed one on this boat this year. On our Uniflite, when we were running the generator one time, I noticed a difference in the exhaust sound, shut down the generator, and found 2 small fish stuck in the intake.
It’s definitely a fuel problem, the fuel pump is dry after it stalls. It’s like there’s a fitting not tight, and the fuel pump looses its vacuum, and the fuel pump is not pulling fuel. I took the fuel system supplying the generator completely apart and found no fuel restrictions of any kind, and the tank selector valve is in perfect working order. I actually bought a new switch valve, and found that the ports were not properly aligned, which wouldn’t allow a full amount of fuel from the factory, unlike the original one,
I am wondering if the 1/4” selector valve currently installed for the generator is big enough, but it’s only a 3 cylinder Westerbeke, so it shouldn’t burn a lot of fuel anyway.
Anyway, another project for after the weekend.
Al
1st Carver 1987 32 Aft Cabin
2nd Carver 1989 4207 Aft Cabin
3rd Carver 1995 350 Voyager
4th (current) 1992 36 Carver Aft Cabin
User avatar

United States of America
g36
Admiral
Admiral
Posts: 2000
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 614 times

Re: Genset running out of fuel

Postby g36 » June 23rd, 2024, 4:03 pm

Why not try a temporary external tank as I suggested earlier to eliminate any issues with valves or fuel starvation concerns?
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5967
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1668 times

Re: Genset running out of fuel

Postby Viper » June 24th, 2024, 6:49 am

I agree