Welcome to Carver Yachts Owners Forum

We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com

You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Kohler 10 kw genny (Model 10e) hard to start

GAS engine, transmission and generator repair and maintenance discussion forum.
User avatar

Topic author United States of America
Mikwallace
CYO Supporter
CYO Supporter
Posts: 102
Joined: August 14th, 2020, 12:22 am
Vessel Info: 1998 Carver 405 AC 7.4 Horizon engines
Location: Lake Guntersville, AL
Has thanked: 117 times
Been thanked: 22 times

Kohler 10 kw genny (Model 10e) hard to start

Postby Mikwallace » July 3rd, 2024, 12:47 pm

Background:
1998 405 Aft Cabin

My generator has always been hard to start. It would take 20-30 seconds of starter operation to start the Generator. I never held the starter button for more than 10 seconds before I’d give a 3 second pause. Once started the generator worked as advertised.

Finally yesterday after 1.5 years of ownership I decided to fix it. Simple fix!

The choke needed adjusting.

Here’s a pic of the generator. I’ve an Ohm meter connected to the choke heater wire to check voltage.

IMG_7026.jpeg




Here’s the choke at cold temp. As you can see it’s not closed. I guess through the years of operation the spring gets weak and won’t close the choke completely?

IMG_7023.jpeg


And finally the voltage to the choke spring.

IMG_7025.jpeg
You do not have the required permissions to view the files attached to this post.
Last edited by Mikwallace on July 3rd, 2024, 2:00 pm, edited 2 times in total.
1959 Larson 16’
1979 Caravelle 18’
1998 Chaparral 2330 7.4 L Mercruiser
2003 Chaparral 260 Ssi 8.1 L VolvoPenta DuoProp
1998 Carver 405 AC 7.4 Horizons
:captain2:
:usa:

User avatar

United States of America
waybomb
CYO Moderator
CYO Moderator
Posts: 2497
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 53 times
Been thanked: 425 times

Re: Kohler 10 kw genny (Model 10e) hard to start

Postby waybomb » July 3rd, 2024, 1:41 pm

Good job!
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
User avatar

United States of America
km1125
Admiral
Admiral
Posts: 3484
Joined: February 28th, 2017, 6:04 pm
Has thanked: 69 times
Been thanked: 1031 times

Re: Kohler 10 kw genny (Model 10e) hard to start

Postby km1125 » July 3rd, 2024, 4:38 pm

That choke thermostat element is adjustable, right (the three screws holding it in place?) I'd adjust so the choke closes all the way, then just hook 12VDC directly to it for about 5 min and see if it opens all the way.

If it doesn't, then you need to replace the choke thermostat element.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5967
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1668 times

Re: Kohler 10 kw genny (Model 10e) hard to start

Postby Viper » July 3rd, 2024, 7:10 pm

:down:
User avatar

United States of America
g36
Admiral
Admiral
Posts: 2000
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 614 times

Re: Kohler 10 kw genny (Model 10e) hard to start

Postby g36 » July 3rd, 2024, 7:32 pm

Same genset in my 405 I had to do that at one time also. I marked it so I knew where I started if I ever needed to go back. Appreciate you posting it in case others need the info.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
User avatar

Canada
bud37
Admiral
Admiral
Posts: 4850
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 575 times
Been thanked: 1202 times

Re: Kohler 10 kw genny (Model 10e) hard to start

Postby bud37 » July 3rd, 2024, 7:55 pm

Thanks for posting......
The above is strictly my opinion.
User avatar

Topic author United States of America
Mikwallace
CYO Supporter
CYO Supporter
Posts: 102
Joined: August 14th, 2020, 12:22 am
Vessel Info: 1998 Carver 405 AC 7.4 Horizon engines
Location: Lake Guntersville, AL
Has thanked: 117 times
Been thanked: 22 times

Re: Kohler 10 kw genny (Model 10e) hard to start

Postby Mikwallace » July 3rd, 2024, 11:58 pm

km1125 wrote:Source of the post That choke thermostat element is adjustable, right (the three screws holding it in place?) I'd adjust so the choke closes all the way, then just hook 12VDC directly to it for about 5 min and see if it opens all the way.

If it doesn't, then you need to replace the choke thermostat element.


Yes, I did exactly that and it works great! I was a little suspicious that I might have to replace the 26 year old spring, but it worked fine. Even went back later to see if it closed after cooling and it did!
1959 Larson 16’