Discharge leak from AC Carver 466
- Alanhuber
- Scurvy Dog

- Posts: 2
- Joined: April 17th, 2016, 8:00 am
- Vessel Info: 2004 Carver 466
- Location: Cincinnati, OH
Discharge leak from AC Carver 466
Unusual one... I have an 04. 466 Carver with a fifth aftermarket AC unit installed behind the aft deck refrigerator , but that is not the problem. It works fine, however, when I turned on the aft CABIN AC Unit at spring start up I found seawater leaking into the condensation pan of the aft DECK AC unit which then overflows into the salon sliding entrance door Gunnel which has an overboard drain. This isn't a slow leak. It sound as if there may be a line that has come off. But I can't understand the connection between the two units as they are completely separate other than sharing a common sea pump. The sea pump has a five outlet spider manifold , separate feed to each AC unit. How can the AFT deck condensation pan be filling whe I turn on the Aft CABIN AC? I don't see how they could be conjoined with one another
- tomschauer
- Admiral

- Posts: 2323
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 326 times
- Been thanked: 602 times
Re: Discharge leak from AC Carver 466
as you have described this, the sea water pump supplies water to all of your a/c units. So, if you turn on any one of them the common pump pumps water to all of them. Therefore, you hopefully have a bad connection out the aft deck unit. worst case is that unit wasn't properly winterized and the condenser (heat exchanger) froze and split.
- Lyndon670
- Admiral

- Posts: 657
- Joined: July 29th, 2013, 11:35 pm
- Vessel Info: 2000 Carver 506
Volvo TAMD74EDC - Location: Georgian Bay
- Has thanked: 124 times
- Been thanked: 140 times
Re: Discharge leak from AC Carver 466
Tom is right on the money. Energize any unit in the system and the pump feeds all of the units, despite their on/off state.
Fingers crossed it's a line off.
Fingers crossed it's a line off.
Lyndon,
2000 Carver 506
FOXY JOE
Volvo 7.4TAMD
Queens Cove Marina
Georgian Bay, Ontario
2000 Carver 506
FOXY JOE
Volvo 7.4TAMD
Queens Cove Marina
Georgian Bay, Ontario
- Alanhuber
- Scurvy Dog

- Posts: 2
- Joined: April 17th, 2016, 8:00 am
- Vessel Info: 2004 Carver 466
- Location: Cincinnati, OH
Re: Discharge leak from AC Carver 466
Thanks. Starting to troubleshoot and hoping for a line off. Appreciate the quick responses.