Water Inlet/Regulator Replacement

Discussion of AC's, plumbing and sanitation related issues.
Post Reply
User avatar
wsp2
Scurvy Dog
Scurvy Dog
Posts: 18
Joined: April 17th, 2024, 12:56 pm
Vessel Info: 1995 Carver 440
Location: Kemah, TX
Has thanked: 10 times
Been thanked: 1 time

Water Inlet/Regulator Replacement

Post by wsp2 »

I need to replace the water inlet, but unfortunately the replacement is slightly larger than the previous one. Jabsco for some reason decided to replace the old style which needed about a 3 1/8" hole with one that's about 3 1/2". I have a couple of questions I'm hoping I can get some feedback on:

- I was thinking about using this method to drill a larger hole: https://youtu.be/vOUfFaIJUqo?si=wP9k6RR7aC-3mwpc. The transom where the inlet is has fiberglass which is about 1/2" thick. Will this method be okay to enlarge the hole?

- Will I need a diamond or carbide tipped drill bit, or will a bi-metal one work okay on the fiberglass? https://www.homedepot.com/p/Milwaukee-3 ... /202327759

- Regarding the plumbing part of this, is it okay to attach the inlet to any cold-water pipe? It appears the inlet pipe had broken off and was capped off somewhere, so I'm not 100% sure where it originally was fed into the system. I'm thinking it was attached to near where the cold water faucet is on the aft shower.

Thanks for any input! Boat is a 1995 440 aft cabin.
Bill P

1995 Carver 440
"Tempest"
Kemah, Texas, USA
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: Water Inlet/Regulator Replacement

Post by Midnightsun »

Bi metal is fine. Sounds odd but start by running the drill in reverse to score the fibreglass and then put it in forward to make the hole. Highly suggest you have a helper holding the end of a shop vac near the hole cup saw while cutting. ;-)

This is a better method IMHO. https://www.youtube.com/watch?v=Ylbwpk2ZyO0
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Water Inlet/Regulator Replacement

Post by Viper »

More than one way to do it, either way mentioned works fine. You can tap into any one of the cold water lines.
User avatar
paulr
First Mate
First Mate
Posts: 130
Joined: September 27th, 2022, 9:36 pm
Vessel Info: 396 CY Aft Cabin 2001 8.1 Crusaders
Location: South Jersey, LBI
Has thanked: 56 times
Been thanked: 32 times

Re: Water Inlet/Regulator Replacement

Post by paulr »

There is an arbor out there that 2 hole hole saw bits can screw on to. You put the 3 1/2" hole saw on first, then screw on the 3 1/8"
The 3 1/8 will keep the bit perfectly centered in the existing hole, then the 3 1/2" will begin to cut. Bi metal is perfect.
User avatar
paulr
First Mate
First Mate
Posts: 130
Joined: September 27th, 2022, 9:36 pm
Vessel Info: 396 CY Aft Cabin 2001 8.1 Crusaders
Location: South Jersey, LBI
Has thanked: 56 times
Been thanked: 32 times

Re: Water Inlet/Regulator Replacement

Post by paulr »

Here is an example of a dual hole saw arbor on amazon.
https://www.amazon.com/Century-Drill-To ... 425&sr=8-3
Post Reply