Hot water tank not filling with water

Discussion of AC's, plumbing and sanitation related issues.
Post Reply
User avatar
tgebler
First Mate
First Mate
Posts: 183
Joined: June 10th, 2018, 1:58 pm
Vessel Info: 2000 396 AC
Location: Pittsburgh
Has thanked: 5 times
Been thanked: 29 times

Hot water tank not filling with water

Post by tgebler »

I have a 2000 396 Aft cabin. I know this is a strange question but my hot water tank does not appear to be filling. I reconnected the hoses after the winter and hooked to shore water. I then turn the spigot in the head to hot water and nothing came out. Help!!
User avatar
buster53
Admiral
Admiral
Posts: 1170
Joined: May 12th, 2017, 10:41 am
Vessel Info: 2001, Carver 356
Location: Gwynn’s Island, VA
Has thanked: 10 times
Been thanked: 285 times

Re: Hot water tank not filling with water

Post by buster53 »

Ok, 2 things…
Make sure the drain spigot near the bottom of the tank is closed.
On my water heater water intake lines, I have 2 valves I can turn on and off to bypass the heater when winterizing. If I recall, one has to be open and the other closed, but not positive. $5 says you have those same 2 valves and they simply aren’t in the correct position.
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: Hot water tank not filling with water

Post by bud37 »

Yup....make sure the bypass valve is closed if you have one, and give the tank time to fill with a hot tap open somewhere. To fill properly it must push the air out of the empty tank.

It'll be something real simple/missed I think on startup, we all have done it .... :-D
FWIW.....The above is just my opinion.
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Hot water tank not filling with water

Post by Viper »

I agree with all the above. If all else fails, some tanks have a check valve on one of the ports, if it’s stuck closed, you won’t get any water from the tank. Usually it’ll look like a regular brass nipple attached in one of the tank’s water ports. A lot of 2 valve by-pass setups also use these check valves as a means of doing away with one valve. If I recall, they’re usually installed on the output/hot port.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: Hot water tank not filling with water

Post by tomschauer »

Also, as viper mentioned there is a check valve on the outlet of the heater. If you connected the inlet water to the outlet of the heater, it will not fill.
User avatar
buster53
Admiral
Admiral
Posts: 1170
Joined: May 12th, 2017, 10:41 am
Vessel Info: 2001, Carver 356
Location: Gwynn’s Island, VA
Has thanked: 10 times
Been thanked: 285 times

Re: Hot water tank not filling with water

Post by buster53 »

tgebler wrote:QR_BBPOST I have a 2000 396 Aft cabin. I know this is a strange question but my hot water tank does not appear to be filling. I reconnected the hoses after the winter and hooked to shore water. I then turn the spigot in the head to hot water and nothing came out. Help!!
So, any updates?
Post Reply