I'm trying to locate valve springs for our Kohler generator, I believe its the original in our 1988 Carver 3607
The genny runs fine on loads of 15amps or less, but anything higher causes the engine to run hard and shutdown.
(1988) Kohler 7.5KW Generator
- g36
- Admiral

- Posts: 2115
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 654 times
Re: (1988) Kohler 7.5KW Generator
Why would jump to valve springs being the cause.have you checked or adjusted them? or compression low etc? Just wondering how you made the jump to the springs?
How about checking temp with the larger load compared to the no load, good water flow or another sensor shutting down the unit.
How about checking temp with the larger load compared to the no load, good water flow or another sensor shutting down the unit.
Last edited by g36 on June 13th, 2016, 2:52 pm, edited 1 time in total.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- Ondercin
- Scurvy Dog

- Posts: 20
- Joined: April 20th, 2015, 5:48 pm
- Vessel Info: 1988 carver 3607 AFT
Penetanguishene - Has thanked: 2 times
- Been thanked: 3 times
Re: (1988) Kohler 7.5KW Generator
Just guessing... When the engine starts to rev higher, it's either starving for fuel or just a guess that one of the valve springs are broken... Just going to pop the cover off now to inspect the valves.
I've replaced the fuel pump with a new electric pump, and the fuel is flowing.
I've replaced the fuel pump with a new electric pump, and the fuel is flowing.
1988 carver 3607 AFT
Penetanguishene
Penetanguishene
- Livinthedream
- Scurvy Dog

- Posts: 3
- Joined: May 28th, 2016, 9:25 am
- Location: Sudbury
- Been thanked: 1 time
Re: (1988) Kohler 7.5KW Generator
I would clean the carb. Most likely leaning out inter load. Or possibly overheating under a big load.
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
Re: (1988) Kohler 7.5KW Generator
Ya could be a number of things. Check the simple stuff first with proper diagnostics before you get into internal engine components.
- Ondercin
- Scurvy Dog

- Posts: 20
- Joined: April 20th, 2015, 5:48 pm
- Vessel Info: 1988 carver 3607 AFT
Penetanguishene - Has thanked: 2 times
- Been thanked: 3 times
Re: (1988) Kohler 7.5KW Generator
So it appears the distributor was off by 1, so the timing was out...
Now the genny runs great, the only thing left to figure out is it's overheating a bit after 3 or so hours and not shutdown down automatically.
Now the genny runs great, the only thing left to figure out is it's overheating a bit after 3 or so hours and not shutdown down automatically.
1988 carver 3607 AFT
Penetanguishene
Penetanguishene
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
Re: (1988) Kohler 7.5KW Generator
Are you saying that it is overheating but not shutting down automatically? If so, you have a faulty overtemp switch. Or do you mean it does shut down automatically?
What do you mean by "a bit" and how are you coming to the conclusion that it is overheating?
There are several things that will cause an overheat; t-stat, restricted raw water flow, faulty pump/impeller, air in system, clogged raw water circuit, timing, bad heat exchanger, bad coolant, low coolant....etc.
- Ondercin
- Scurvy Dog

- Posts: 20
- Joined: April 20th, 2015, 5:48 pm
- Vessel Info: 1988 carver 3607 AFT
Penetanguishene - Has thanked: 2 times
- Been thanked: 3 times
Re: (1988) Kohler 7.5KW Generator
It's not shutting down, after about 3 hours the temp is sitting around 160.. I have good water flow coming out the exhaust. I checked the impeller (twice) and it's perfect!
I am guessing the overtemp switch, but I haven't been able to test it yet... Perhaps on Saturday over a few beers!
I am guessing the overtemp switch, but I haven't been able to test it yet... Perhaps on Saturday over a few beers!
1988 carver 3607 AFT
Penetanguishene
Penetanguishene
-
Viper
- CYO Supporter

- Posts: 6266
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 475 times
- Been thanked: 1791 times
Re: (1988) Kohler 7.5KW Generator
I'll have to check specs but I don't think 160 is an issue. It's normal temp for closed cooling main engines, I just don't recall what the spec is for this generator. Pretty sure the over-temp switch doesn't activates at about 200. Again, I'll have to check. If you have the manual, it'll be in there.