Kohler 6.5 genset issue

Post by dabluzdude »

1991 era Kohler 6.5. Cranks easily, runs smoothly for about 40 minutes under load, then dies. Will re-crank immediately and run for about 10-12 minutes, then shuts down. good waterflow, good oil level. any ideas? thanks in advance.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: Kohler 6.5 genset issue

Post by tomschauer »

Not sure of you model. If you have an ESV with a Honda engine, high water temp, high exhaust temp, or low oil pressure could shut it down. Also a fuel delivery problem could be the culprit with any engine. The Honda also has an anti diesel solenoid that actually cuts off all air flow, the solenoid, connector to the solenoid or the control board could be the cause.

If it spits and sputters before dying I would look at the fuel system. If it shuts down instantly, I would look at the safeties, checking the water flow first. The exhaust hose should be warm not hot to the touch when running.
User avatar
dabluzdude
Scurvy Dog
Scurvy Dog
Posts: 15
Joined: April 18th, 2016, 5:19 pm
Vessel Info: 1991 33AC
Location: Alabama
Has thanked: 1 time
Been thanked: 2 times

Re: Kohler 6.5 genset issue

Post by dabluzdude »

Thanks, it's a 6.5CZ. When it shuts down, it shuts down cleanly. when you crank it back up, it cranks easily and runs smoothly. no spit nor sputter.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: Kohler 6.5 genset issue

Post by tomschauer »

Look at some of the other Kohler posts on here. I believe Viper posted a service manual for the CZ.
User avatar
dabluzdude
Scurvy Dog
Scurvy Dog
Posts: 15
Joined: April 18th, 2016, 5:19 pm
Vessel Info: 1991 33AC
Location: Alabama
Has thanked: 1 time
Been thanked: 2 times

Re: Kohler 6.5 genset issue

Post by dabluzdude »

Thanks. I've searched several forums and read hundreds of generator posts, Most seem to be associated with "it only runs while I hold the start switch", haven't seen anything that sounds like my issue. Found several Kohler service manuals but nothing specifically for the 6.5CZ. I feel like it is one of the safety's that is shutting it down, just have to spend some more time with it.
User avatar
mjk1040
Admiral
Admiral
Posts: 1531
Joined: July 30th, 2015, 8:15 am
Vessel Info: 1998 355 AC/MY "Deja Vu"
Location: Savannah, NY
Has thanked: 9 times
Been thanked: 248 times

Re: Kohler 6.5 genset issue

Post by mjk1040 »

I think you are on the right track with one of the safety's causing your issue. Mike
Mike :down:
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: Kohler 6.5 genset issue

Post by tomschauer »

If its a high exhaust temp or high coolant temp your not moving enough water. When these fail, they fail to ground on most models. The high exhaust would be quicker to reset than the high coolant temp, I would start there.
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Kohler 6.5 genset issue

Post by Viper »

Could be a number of things; one of the sensors noted above is failing, control board failing, run relay, generator not outputting, fuel delivery issue including vapour lock, puel pump/pressure regulator, anti-dieseling solenoid, spark plugs, coil failure, etc.

In the service manual below, go to the troubleshooting section and check the "Generator shuts down by itself" section. I believe there's also a section on how to diagnose the control board. Keep us posted....

http://www.google.ca/url?url=http://www.generatorparts.net/resources/tp5338.pdf&rct=j&frm=1&q=&esrc=s&sa=U&ved=0ahUKEwi0tfa9vvDOAhVD7R4KHQxfBNsQFggWMAA&usg=AFQjCNG63FrpWVFJ2x8eQ62NZxqw-PpNjw

http://www.google.ca/url?url=http://www.partsfortechs.com/resources/tp5339.pdf&rct=j&frm=1&q=&esrc=s&sa=U&ved=0ahUKEwi0tfa9vvDOAhVD7R4KHQxfBNsQFggbMAE&usg=AFQjCNGNhPwlIkNaHyJV1k0YRDQTLW_snw
User avatar
dabluzdude
Scurvy Dog
Scurvy Dog
Posts: 15
Joined: April 18th, 2016, 5:19 pm
Vessel Info: 1991 33AC
Location: Alabama
Has thanked: 1 time
Been thanked: 2 times

Re: Kohler 6.5 genset issue

Post by dabluzdude »

Awesome! Thanks for the info. I will keep ya'll posted.
User avatar
WeekendLove2
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: December 27th, 2014, 7:44 am
Vessel Info: Carver 1988 42 aft cabin
Location: Lake Texoma

Re: Kohler 6.5 genset issue

Post by WeekendLove2 »

I would check the strainer first, then if clean check oil pressure and water temp sending units. Sounds like water temp may be getting high and cutting off automatically.