110 volt circuit breakers

Post by jbmaclean »

On my electrical distribution panel on 1995 440 the 110 volt side does not work when generator is running. Both sides are OK when shore power is connected and the side running the air conditioners is ok when genny is running too. Any ideas where to start? Some have suggested the breaker is bad. Anything else I can Check>\?
User avatar
waybomb
CYO Moderator
CYO Moderator
Posts: 2745
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 69 times
Been thanked: 492 times

Re: 110 volt circuit breakers

Post by waybomb »

Does your boat automatically switch between shore and generator?
If so, there are two relays that do the automatic switching. One of them is probably faulty.
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
User avatar
jbmaclean
Scurvy Dog
Scurvy Dog
Posts: 8
Joined: August 14th, 2015, 8:51 pm
Vessel Info: 1995
440
Cat diesels 3116 with 950 hours
Home Port is Wye Heritage in Midland

Re: 110 volt circuit breakers

Post by jbmaclean »

I don't have auto switching. There is a slider that moves back and forth only allowing either shore power breaker or generator breaker to be in the on position.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: 110 volt circuit breakers

Post by tomschauer »

If that is the case, it is most likely the breaker. Do you know how to safely use a voltage tester? If so with the gen running check voltage on the in and out of the gen breaker (the one that is one when in the generator position) in question. Most likely it has failed
User avatar
jbmaclean
Scurvy Dog
Scurvy Dog
Posts: 8
Joined: August 14th, 2015, 8:51 pm
Vessel Info: 1995
440
Cat diesels 3116 with 950 hours
Home Port is Wye Heritage in Midland

Re: 110 volt circuit breakers

Post by jbmaclean »

Thanks for your input. Will check next week when I get back to the boat. The wife thinks I need to go to her family reunion this weekend. Will let you know what happens next week.
User avatar
Samuel
Scurvy Dog
Scurvy Dog
Posts: 23
Joined: June 9th, 2017, 7:41 am
Has thanked: 1 time
Been thanked: 1 time

Re: 110 volt circuit breakers

Post by Samuel »

ON your generator you should have a switch so you can start it and next to it you should have another switch make sure the switch is on and the fuse is good. That switch powers everything to your panel when on.
User avatar
jbmaclean
Scurvy Dog
Scurvy Dog
Posts: 8
Joined: August 14th, 2015, 8:51 pm
Vessel Info: 1995
440
Cat diesels 3116 with 950 hours
Home Port is Wye Heritage in Midland

Re: 110 volt circuit breakers

Post by jbmaclean »

Samuel thanks for the input. I do have a switch on the generator and it is powered on. The switch must be OK as the Air Conditioner side on the AC panel is live. Do you know if there are any other fuses between the generator and the Circuit breakers on the electrical distribution panel?
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: 110 volt circuit breakers

Post by tomschauer »

Normally there are no other switches or fuses between the gen and the breakers in your ac distribution panel.
User avatar
waybomb
CYO Moderator
CYO Moderator
Posts: 2745
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 69 times
Been thanked: 492 times

Re: 110 volt circuit breakers

Post by waybomb »

If you do not have a gen/line breaker, then there is a set of relays that switch between generator and line.
The one for the ac is working. The other isn't.
I have no idea where they are on your boat.
On mine, it's on a black box under the seat right next to the incoming line.
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
User avatar
jbmaclean
Scurvy Dog
Scurvy Dog
Posts: 8
Joined: August 14th, 2015, 8:51 pm
Vessel Info: 1995
440
Cat diesels 3116 with 950 hours
Home Port is Wye Heritage in Midland

Re: 110 volt circuit breakers

Post by jbmaclean »

Marina fixed the problem. The generator has one switch for the breaker that powers the 2 sides of the electrical panel. The breaker has 2 sides to it and one side was faulty. They got a new breaker from kohler and everything is good. I have never seen a breaker that actually has 2 outputs. Go figure it is a boat. Thanks to all who offered help.