Fresh Water Pump

Discussion of AC's, plumbing and sanitation related issues.
User avatar
mjk1040
Admiral
Admiral
Posts: 1531
Joined: July 30th, 2015, 8:15 am
Vessel Info: 1998 355 AC/MY "Deja Vu"
Location: Savannah, NY
Has thanked: 9 times
Been thanked: 248 times

Fresh Water Pump

Post by mjk1040 »

Well it seems our fresh water pump decided to crap out while winterizing our water system. Pump is presently a ShurFlo 2088-423-344 Diaphragm Pump. 2.8gpm, 12volt, 7.5max, 45psi, built 04/1999. Before I buy the same pump again, was wondering if anyone would recommend a upgrade unit and for what reason. Now mind you I have not double checked supply flow to the pump or taken the inlet filter apart and see if its possibly clogged since I have the system full of -50 Marine/RV antifreeze. Looking forward to all your suggestions!
Mike :down:
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
User avatar
RGrew176
Admiral
Admiral
Posts: 6652
Joined: August 17th, 2015, 4:07 am
Vessel Info: 2023 SunTracker Party Barge 22 DLX
Location: Southgate, MI.
Has thanked: 72 times
Been thanked: 470 times

Re: Fresh Water Pump

Post by RGrew176 »

My thoughts are if the pump has failed and it is original and it has lasted from 1999 to 2018 why not replace with the same model. The original lasted 18+ years why mess with success. Just a thought.
Rick Grew

2025 Godfrey Xperience 2286 SFLX

2004 Past Commodore
West River Yacht & Cruising Club
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: Fresh Water Pump

Post by Midnightsun »

There has really been no great advancement in pumps except for the newer variable speed on demand pumps out there. That being said, the variable pumps have been very unreliable! Stick with what you have IMHO, maybe up grade the flow by purchasing a larger unit if required.
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
User avatar
mjk1040
Admiral
Admiral
Posts: 1531
Joined: July 30th, 2015, 8:15 am
Vessel Info: 1998 355 AC/MY "Deja Vu"
Location: Savannah, NY
Has thanked: 9 times
Been thanked: 248 times

Re: Fresh Water Pump

Post by mjk1040 »

The pump label says 04/1999, however it looks like the pump has been removed, repaired and reinstalled because it is apparent its not completely installed or mounted as it should be as an OEM installation. I believe a previous owner may have repaired it 6 years ago if my memory serves me right. Looking at the cost of the repair parts kits for these pumps, might just as well buy a new complete pump. I agree with your opinions, if it worked that long stick with it.
Mike :down:
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Fresh Water Pump

Post by Viper »

Pretty sure that model is discontinued though it's likely there is a similar replacement. Hans is right about the electronic pumps. I've replaced a few of them though all the ones I've replaced under warranty are still working two years later so perhaps improvements have been made. Having said that, it seems that when a hardware design incorporates a circuit board, that's usually the part that fails sooner than expected. The design provides a couple of benefits but one has to wonder if it's worth it.

Careful when considering going with a higher capacity pump. You must ensure that the existing wiring/circuit is rated for the extra load usually associated with a higher volume unit.
User avatar
km1125
Admiral
Admiral
Posts: 3657
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: Fresh Water Pump

Post by km1125 »

If the motor still runs but it's not pumping, sometimes it's a simple as taking it all apart and cleaning out the valves and reassembling.
User avatar
mjk1040
Admiral
Admiral
Posts: 1531
Joined: July 30th, 2015, 8:15 am
Vessel Info: 1998 355 AC/MY "Deja Vu"
Location: Savannah, NY
Has thanked: 9 times
Been thanked: 248 times

Re: Fresh Water Pump

Post by mjk1040 »

That's the plan km, of course no shut offs on any of the lines so going to have to find some line plugs so all the rv antifreeze doesn't run all over the place. Thanks all.
Mike :down:
I'd Rather Be Boating!
1989 Sea Ray Seville
1986 Carver Mariner 32'
1990's Thompson 22' Cuddy Cabin
1990's 4Winns 245 Vista Cruiser
1980's Thompson 19' Open Bow
User avatar
Sailor Jerry
Scurvy Dog
Scurvy Dog
Posts: 33
Joined: August 1st, 2016, 2:56 pm
Vessel Info: 1996 Carver 355
Location: Mississippi
Has thanked: 2 times
Been thanked: 8 times

Re: Fresh Water Pump

Post by Sailor Jerry »

The fresh water pump on my 355 went out and a local marine mechanic suggested replacing it with a size larger. He said I'd get better water pressure and flow. Well, I did as he suggested, and did get better pressure. However, I continually had issues with the pump pulsing on and off when the system was not in use. It was so annoying I ended up replacing the replacement with a pump identical to the original. No problems!
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: Fresh Water Pump

Post by bud37 »

Sailor Jerry wrote:Qr Bbpost The fresh water pump on my 355 went out and a local marine mechanic suggested replacing it with a size larger. He said I'd get better water pressure and flow. Well, I did as he suggested, and did get better pressure. However, I continually had issues with the pump pulsing on and off when the system was not in use. It was so annoying I ended up replacing the replacement with a pump identical to the original. No problems!

Good tip for folks, thanks.......You may have had a small leak that only showed itself at the higher pressure, was fine at the lower original pressure.......
FWIW.....The above is just my opinion.
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: Fresh Water Pump

Post by Midnightsun »

Cycling on/off when not in use can only happen if the pressure drops as in a leak or the unit sensor is defective or the check valve has a small leak. It is not the larger output that caused this.
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
Post Reply