New Inverter/House Bank

Post Reply
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

I took some pictures of the terminals that are below the landed cables for future reference (kinda dumb of victron to have those jammed underneath the main power cables like that):
IMG_20190929_1445220.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

Here's the other side:
IMG_20190929_1445299.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

Mounted the charger in its temporary location for testing and commissioning, though I still need to open up a larger access hatch for it's final home in this cabinet:
IMG_20190929_1611528.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

I think I'm going to use a custom panel from these folks to enlarge that access:
https://www.boatoutfitters.com/parts/doors/custom-doors
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

Now I need to figure out how to get the new bank attached to the existing dc. This switch is going to go bye bye:
IMG_20191002_1755374.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

Oh god what have I gotten myself into:
IMG_20191002_1759453.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

I understand what is going on here generally not specifically, if you know what I'm saying. There are feeds coming in from what used to be two distinct battery banks of which now only the starboard bank remains active, and three switches for essential circuits (bilge pumps). There are two switches that were wired in to disable the voltage meters on the main panel (not sure why). There should be two feeds coming out to go to the two main dc breakers on the panel, which I assume come from the two 60a push-type breakers that are tied together in here? I've gotten a little lost that's for sure. Gonna hafta bust out the meter. I'm going to label things as I go:
IMG_20191002_1811266.jpg

IMG_20191002_1811266.jpg

IMG_20191002_1801541.jpg

IMG_20191002_1819241.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

On another note - the compressor for the AC kicked on while I had my hands on all these wires and scared the bejesus out of me!

Is this amount of Frost normal when using reverse cycle heat?
IMG_20191002_1754389.jpg


Also - what is the easiest way to clean this? Compressed air?
IMG_20191002_1754266.jpg
You do not have the required permissions to view the files attached to this post.
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: New Inverter/House Bank

Post by bud37 »

Did you find the original charger feeds to that panel switch.....if not I would check continuity on each of those cables to find where each one goes....Carver did some interesting wiring runs.....do you have the wiring schematic ?

To add, Looks a little dirty in that pic...just vacuum it..
FWIW.....The above is just my opinion.
User avatar
vineyardgray
Captain
Captain
Posts: 262
Joined: July 15th, 2018, 10:26 pm
Has thanked: 128 times
Been thanked: 33 times
Contact:

Re: New Inverter/House Bank

Post by vineyardgray »

I am thankful that this article came out right while I'm (attempting) to wire up a similar system. I like the idea of dc to dc chargers for the start bank. Also regulating the two alternators and using all that juice for the house bank is a very interesting idea as well:

https://seabits.com/victron-wakespeed-b ... er-system/
M/V Gilded Splinter
1988 Carver
3867 Santego
PCYC
Post Reply