Welcome to Carver Yachts Owners Forum

We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com

You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

1989 3807 Where is the Generator Start Button

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author United States of America
justtls
Scurvy Dog
Scurvy Dog
Posts: 14
Joined: January 12th, 2015, 1:18 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Has thanked: 6 times

1989 3807 Where is the Generator Start Button

Postby justtls » January 12th, 2015, 1:24 pm

Just purchased an 89 3807, I see a toggle on the main panel for the Genset but no start button or meter, any ideas? Thanks for taking the time to review my question, any help would be greatly appreciated.
Regards,
Terry

User avatar

eric_b
Scurvy Dog
Scurvy Dog
Posts: 38
Joined: November 13th, 2013, 1:40 pm
Vessel Info: 1986 Carver 3227 Convertible
Location: Marblehead, OH
Been thanked: 1 time

Re: 1989 3807 Where is the Generator Start Button

Postby eric_b » January 12th, 2015, 3:59 pm

The toggle you are looking at should also start the genset, it should be a 3 way toggle, stop/neutral/start. There will also be a toggle/button directly on the generator. What model genset does the boat have? Mine is an ONAN MCCK 6.5 gas genset.
1986 Carver 3227 Convertible
User avatar

Topic author United States of America
justtls
Scurvy Dog
Scurvy Dog
Posts: 14
Joined: January 12th, 2015, 1:18 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Has thanked: 6 times

Re: 1989 3807 Where is the Generator Start Button

Postby justtls » January 14th, 2015, 1:13 pm

eric_b wrote:The toggle you are looking at should also start the genset, it should be a 3 way toggle, stop/neutral/start. There will also be a toggle/button directly on the generator. What model genset does the boat have? Mine is an ONAN MCCK 6.5 gas genset.


Thanks for the info. Mine has the Koehler 7.5R . The only Switch I can find is the one on the main panel, its a two way toggle that just has off/Start, however I was reading something yesterday that would indicate that the the two way toggle switch may be the only one and that the Generator just stops the starter once the engine is started. I was looking for the remote control panel that is apparently an option because when I tried to use the start toggle nothing happened. I guess I will need to check the connections etc from the battery/Switch. Thanks again for your time.

Regards,
Terry
User avatar

eric_b
Scurvy Dog
Scurvy Dog
Posts: 38
Joined: November 13th, 2013, 1:40 pm
Vessel Info: 1986 Carver 3227 Convertible
Location: Marblehead, OH
Been thanked: 1 time

Re: 1989 3807 Where is the Generator Start Button

Postby eric_b » January 14th, 2015, 5:21 pm

Is there anything in the owners manual about the start/stop procedures for the generator? That might be a good place to start, there is a section in my owners manual for it.
1986 Carver 3227 Convertible
User avatar

United States of America
g36
Admiral
Admiral
Posts: 2002
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 615 times

Re: 1989 3807 Where is the Generator Start Button

Postby g36 » January 15th, 2015, 10:19 am

the toggle is momentary both ways and center postion off. hold one way to start and let go once started to stop unit push other way hold till genset stops and let go
there is a switch on the genset that operates the same way if it wont start form either then time to check battery switch but you should at least here it trying if not then the relay the switches activate may need to be looked at
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
User avatar

Topic author United States of America
justtls
Scurvy Dog
Scurvy Dog
Posts: 14
Joined: January 12th, 2015, 1:18 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Has thanked: 6 times

Re: 1989 3807 Where is the Generator Start Button

Postby justtls » June 18th, 2015, 9:28 pm

BTW I wanted to thank you all for your time and info on the Genset issue. It turn out that the switch on the unit is by touch only as you cant see it that side of the unit but the problem it turns out was simply the Battery being dead and not connected to the charging system. Thanks again.
User avatar

Topic author United States of America
justtls
Scurvy Dog
Scurvy Dog
Posts: 14
Joined: January 12th, 2015, 1:18 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Has thanked: 6 times

Re: 1989 3807 Where is the Generator Start Button

Postby justtls » June 18th, 2015, 9:40 pm

RESOLVED!

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5975
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1671 times

Re: 1989 3807 Where is the Generator Start Button

Postby Viper » July 12th, 2015, 1:11 am

Glad you got her going. For the benefit others, on my 1989 3807, the switch at the AC panel is an ON, OFF switch that stays in the ON position when you let it go. The Kohler disengages the start circuit on it's own. There is a switch on the generator to start and stop the unit and a "Remote" position that must be selected if you want to start the unit from the AC panel.