Welcome to Carver Yachts Owners Forum
We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com
You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!
110ac panel 2 issue
- Mike28
- Scurvy Dog
- Posts: 3
- Joined: May 17th, 2021, 12:14 pm
- Vessel Info: 1989 32 mid cabi
- Location: Harrison Township Michigan
- Has thanked: 3 times
110ac panel 2 issue
Last year I bought a 1989 32 Montego.
Everything worked great. We put the boat back in the water about 3 weeks ago and everything seemed to be ok... until I tried to turn the heat on.
Before flipping the A/C/heat breaker "on" I had the main breaket on panel 2 "on" and the volt gauge was reading 110 volts. As soon as I flipped the A/C/heat breaker panel 2 went dead and I can't get it back. I run a Y splitter to the shore power inlets at the boat since my dock only has one 30 amp plug, which has not been a problem before. I tried switching the Y splitter to see if the problem moved to panel 1. The problem was still panel 2 is dead. I removed the panel and checked voltage with a meter and I have no power to panel 2.
The wiring diagram I have from Carver shows "dual shore transfer relays". My question is... wouldn't I only have those if I had a generator? I do not have a generator.
Does anyone know if there are hidden breakers somewhere? I feel like I've looked in every spot but there must be something I'm missing.
- Midnightsun
- CYO Supporter
- Posts: 2924
- Joined: March 27th, 2016, 2:27 pm
- Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's - Location: Montreal, Canada
- Has thanked: 268 times
- Been thanked: 1153 times
Re: 110ac panel 2 issue
A good reminder to all with an older boat, check the wires at the inlet connection as these do go bad. Will not hurt the least to remove, cut away a couple inches and reinstall on a fresh lead. Most boat fires originate at this connection.
Welcome to the forum by they way.
- Mike28
- Scurvy Dog
- Posts: 3
- Joined: May 17th, 2021, 12:14 pm
- Vessel Info: 1989 32 mid cabi
- Location: Harrison Township Michigan
- Has thanked: 3 times
Re: 110ac panel 2 issue
- Midnightsun
- CYO Supporter
- Posts: 2924
- Joined: March 27th, 2016, 2:27 pm
- Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's - Location: Montreal, Canada
- Has thanked: 268 times
- Been thanked: 1153 times
Re: 110ac panel 2 issue
- g36
- Admiral
- Posts: 2002
- Joined: April 7th, 2014, 6:07 pm
- Vessel Info: 1997 Carver 405
- Location: Soddy Daisy TN.
- Has thanked: 7 times
- Been thanked: 615 times
Re: 110ac panel 2 issue
Crusader xli
The Black Pearl
Soddy Daisy Tn.
- Cooler
- Admiral
- Posts: 1634
- Joined: May 22nd, 2018, 12:09 pm
- Vessel Info: 1995 Carver 330 Mariner
Twin 350XL Crusaders
Home port: Menominee, MI - Location: Green Bay, WI
- Has thanked: 68 times
- Been thanked: 390 times
Re: 110ac panel 2 issue
( All weather people have to say this on air, near lakes )
- chpsk8
- First Mate
- Posts: 163
- Joined: July 2nd, 2018, 10:13 pm
- Vessel Info: 1995 Carver Aft Cabin Motor Yacht... Hull #001
- Has thanked: 27 times
- Been thanked: 75 times
Re: 110ac panel 2 issue
- bud37
- Admiral
- Posts: 4865
- Joined: April 23rd, 2015, 10:22 pm
- Has thanked: 579 times
- Been thanked: 1210 times
Re: 110ac panel 2 issue
- buster53
- Admiral
- Posts: 1026
- Joined: May 12th, 2017, 10:41 am
- Vessel Info: 2001, Carver 356
- Location: Lower Potomac, VA
- Has thanked: 9 times
- Been thanked: 261 times
Re: 110ac panel 2 issue
g36 wrote:My 405 has breakers at the shore inlet locations also
I don’t think builders were doing those breakers back in 1989, when the OP’s boat was built.
-
- CYO Supporter
- Posts: 2307
- Joined: March 28th, 2016, 10:52 pm
- Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X - Location: upper chesapeake bay
- Has thanked: 324 times
- Been thanked: 595 times
Re: 110ac panel 2 issue
I assume you shut off the breaker for the a/c before reconnecting the power.
If you have a single 30 amp power supply at the dock, you most likely wont be able to run the a/c and water heater at the same time.
Return to “Carver Yachts Forum - Model Discussion”