ac Freon refill

Post by pepmyster »

Hello to all!!!!! I had a problem which was answered to the cause of one of my ac units frosting up. The logical solution was that it was low on Freon, ( thanks Hans). Has anyone done this to their units? I found the the service port which was labeled "suction". Makes sense. If you have done this, what did you use as a product? I'm almost sure it's R12. Thanks in advance.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: ac Freon refill

Post by tomschauer »

Depending on the years its either r-22 or r-410a.
It should have a label stating the refrigerant type and the charge weight.
User avatar
g36
Admiral
Admiral
Posts: 2115
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 654 times

Re: ac Freon refill

Post by g36 »

You must make sure what refrigerant is in the unit. There should be a label for kind and amount it is using.. If you don't have any guages then your just blindly putting it in, which isn't the best option . It can be done but you can also screw it up and can be dangerous ,Also if your low you have leak., if it is r12 its pretty expensive now if you can find it.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
User avatar
buster53
Admiral
Admiral
Posts: 1170
Joined: May 12th, 2017, 10:41 am
Vessel Info: 2001, Carver 356
Location: Gwynn’s Island, VA
Has thanked: 10 times
Been thanked: 285 times

Re: ac Freon refill

Post by buster53 »

pepmyster wrote:QR_BBPOST I'm almost sure it's R12.
Before doing anything, you need to BE Sure, not almost sure.
User avatar
pepmyster
Admiral
Admiral
Posts: 1035
Joined: June 5th, 2018, 7:17 am
Vessel Info: 2004 Carver 360 Sport Sedan
8.1 Volvo Penta
Fresh water boating
Location: Ottawa
Has thanked: 492 times
Been thanked: 211 times

Re: ac Freon refill

Post by pepmyster »

2004, You could be right about the R22. I read a lot and many have written that it was R22.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: ac Freon refill

Post by tomschauer »

Its definitely not R-12.
For 2004 it should be 410a, but could still be 22.
22 is quite expensive now. About $35 a pound wholesale.
So if its low, you want to find and repair the leak, not just juice it up.
User avatar
pepmyster
Admiral
Admiral
Posts: 1035
Joined: June 5th, 2018, 7:17 am
Vessel Info: 2004 Carver 360 Sport Sedan
8.1 Volvo Penta
Fresh water boating
Location: Ottawa
Has thanked: 492 times
Been thanked: 211 times

Re: ac Freon refill

Post by pepmyster »

I get that. It must be missing just enough Freon to frost. It working but frosts. After all those years, not surprised it missing a bit.
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Re: ac Freon refill

Post by tomschauer »

Low airflow will also make it frost.
Dirty coil etc.
User avatar
pepmyster
Admiral
Admiral
Posts: 1035
Joined: June 5th, 2018, 7:17 am
Vessel Info: 2004 Carver 360 Sport Sedan
8.1 Volvo Penta
Fresh water boating
Location: Ottawa
Has thanked: 492 times
Been thanked: 211 times

Re: ac Freon refill

Post by pepmyster »

I cleaned the condenser, air filter. checked the fins. I put a fan directed at it also, same result.
User avatar
km1125
Admiral
Admiral
Posts: 3658
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: ac Freon refill

Post by km1125 »

tomschauer wrote:QR_BBPOST Low airflow will also make it frost.
Dirty coil etc.
^^^THIS.

I've had a lot of spirited "discussions" with folks on this topic. If you're passing enough 80F air over something, it CAN'T freeze. Something must be restricting the flow somewhere for the evap to even get close to freezing temperatures.

Low pressures in the system will lower both the condensor and evap temperatures, but if the evap coils have enough flow over them the refridgerant will absorb all the BTUs they need to get the temps over freezing VERY quickly. There may be portions of the evap coils that don't get flow that get cold and establish frost or ice, but that should never grow over the rest of the coil if there is enough return air flow.