You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

1993 Kohler 6.5CZ23 only runs while holding start button

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author United States of America
jeffnnoble
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: July 27th, 2021, 6:41 am
Vessel Info: 1993 Carver 350 Aft
Location: Grand Haven Mi.
Has thanked: 11 times
Been thanked: 3 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby jeffnnoble » July 29th, 2021, 11:09 am

Thanks all for you help.

Any chance anyone has a copy of the Kohler 6.5cz Service Manual
Last edited by jeffnnoble on July 29th, 2021, 11:34 am, edited 2 times in total.

User avatar

Topic author United States of America
jeffnnoble
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: July 27th, 2021, 6:41 am
Vessel Info: 1993 Carver 350 Aft
Location: Grand Haven Mi.
Has thanked: 11 times
Been thanked: 3 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby jeffnnoble » July 29th, 2021, 11:29 am

Thanks for your reply's please bare with me as I have a few additional questions that I will preface with; electronics have been a bit of a nemesis for me.

Tom, Thanks for your reply. Can you expand on what indicator/s lead you to think capacitor? Asking because I'm not sure of the role of the capacitor is in this system hoping you can shed some light.

Midnightsun, Do you know if the oil pressure switch is open or closed when the Kohler generator is OFF (not running)? Asking because "The oil pressure sensor simply makes contact to ground when pressure is detected." appears to be opposite of the video. I'm ok with either just confused if the switch in this application should be open or closed when the generator is off.
For what it is worth the wiring diagram shows a drawing of a closed oil pressure switch, the same diagram also shows the other safety switches (one Engine switch & two Exhaust temp switches as open)
User avatar

Canada
bud37
Admiral
Admiral
Posts: 4865
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 579 times
Been thanked: 1210 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby bud37 » July 29th, 2021, 4:41 pm

Jeff, is that schematic something you could post here........I am sure there are a few things that could cause your problem other than the sensor so you will have to cross things off as you go in my opinion.....tough to diagnose in a forum setting.
The above is strictly my opinion.

United States of America
tomschauer
CYO Supporter
CYO Supporter
Posts: 2307
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 324 times
Been thanked: 595 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby tomschauer » July 29th, 2021, 6:38 pm

With a bad capacitor, it wont generate output voltage. Without output voltage, your run relay will not latch. Capacitor should be less than $10.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5975
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1671 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby Viper » July 29th, 2021, 9:30 pm

A few good thoughts here for sure, could be a few things. Don't rule out a bad Start/Stop switch though. Having a faulty one at either end will cause the same symptom no mater which switch you try to use. I had this symptom on a Kohler but can't remember the model. A real head scratcher because I checked just about everything including the remote switch at the panel. Finally decided to also do a continuity test on the switch at the unit and that's what it turned out to be, replaced it and all good.
User avatar

Topic author United States of America
jeffnnoble
Scurvy Dog
Scurvy Dog
Posts: 6
Joined: July 27th, 2021, 6:41 am
Vessel Info: 1993 Carver 350 Aft
Location: Grand Haven Mi.
Has thanked: 11 times
Been thanked: 3 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby jeffnnoble » August 2nd, 2021, 6:32 am

Thanks to all who took the time to read this series of posts.
GOOD NEWS! We are up and running again!

After Reading the additional replies from July 29th and doing more research on each as luck would have it Tom was on to something. In my original post I indicated that while holding the start switch I was getting no voltage. Upon inspection the capacitor looked fine, and did not have any short to ground from either terminal. I did however notice with my multimeter that there was no stored volts AC or DC. The side of the capacitor was rated for 1000 VDC or 440VAC so using a 9V battery tried to introduce voltage to see if the capacitor would hold or store voltage, and it would not. I was able to locate a replacement at a local Kohler dealer, and on a Saturday morning too! As Luck would have it as I was exiting the Kohler repair tech had just stopped in to pick up parts for a repair he was in the middle of. Giving me a few minutes of his time and running down my story, basically my initial post, he interrupted me at no output voltage and said I need to "replace the capacitor." "99.9% of the time a situation like mine with no output voltage is a bad capacitor." Showing him what I had just purchased he replied "That'll do it! which is a good thing because I'm booked out foe the next 6 weeks."
also for those interested the LED1 is the run circuit that Tom mentioned above and will illuminate with output voltage.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 5975
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 455 times
Been thanked: 1671 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby Viper » August 2nd, 2021, 6:50 am

Thanks for following up. Glad you solved the issue :down:

United States of America
tomschauer
CYO Supporter
CYO Supporter
Posts: 2307
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 324 times
Been thanked: 595 times

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby tomschauer » August 2nd, 2021, 7:19 pm

Luck? I think not :lol:
Glad your back to generating!
User avatar

United States of America
rcaron
Scurvy Dog
Scurvy Dog
Posts: 1
Joined: February 5th, 2022, 5:02 pm
Vessel Info: 2005 Voyager 56 D12 Volvo Penta Kholer 23 KW Generator Loaded
Location: Kemah Texas

Re: 1993 Kohler 6.5CZ23 only runs while holding start button

Postby rcaron » February 5th, 2022, 5:16 pm

I am looking for fuel gage for 2005 Voyager 56. Does anyone Know where I can buy one? The fuel gage does shows both tanks.

Thank you