I’m looking at purchasing a 55 marquis. The boat has 2 50amp power cords but our marinas only have 1 50amp receiver. So how do you guys get around this and be able to run the boat on shore power?
User avatar
Midnightsun
CYO Supporter
CYO Supporter
Posts: 2984
Joined: March 27th, 2016, 2:27 pm
Vessel Info: The Midnight Sun
2007 41CMY
Volvo D6-370's
Location: Montreal, Canada
Has thanked: 272 times
Been thanked: 1193 times

Re: 50 amp power y spec

Post by Midnightsun »

Need a little more info. Are your boat inlets inlets 50a 125/250 or 50a 125?

The 125/250 has 2, dog leg prongs compared to the 125 which has only 1. https://www.westmarine.com/WestAdvisor/DIY-Shore-Power
Cheers, Hans
2007 Carver 41 CMY
Twin Volvo D6-370's
Montreal, Canada
Midnight Sun I Photos
User avatar
Geaux Time
Scurvy Dog
Scurvy Dog
Posts: 7
Joined: July 6th, 2022, 11:50 am

Re: 50 amp power y spec

Post by Geaux Time »

The 2 power cords coming from the boat are both 50a 125/250 and I have one 50a 125/250 receptacle in the pedestal at the dock. Is there anyway to make this work?
User avatar
km1125
Admiral
Admiral
Posts: 3657
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 50 amp power y spec

Post by km1125 »

Geaux Time wrote:QR_BBPOST The 2 power cords coming from the boat are both 50a 125/250 and I have one 50a 125/250 receptacle in the pedestal at the dock. Is there anyway to make this work?
Yep... just get a 50A 125/250 "Y" adapter. You just have to manage your peak loads so you don't trip the shore breaker.
User avatar
Geaux Time
Scurvy Dog
Scurvy Dog
Posts: 7
Joined: July 6th, 2022, 11:50 am

Re: 50 amp power y spec

Post by Geaux Time »

km1125 wrote:QR_BBPOST
Geaux Time wrote:QR_BBPOST The 2 power cords coming from the boat are both 50a 125/250 and I have one 50a 125/250 receptacle in the pedestal at the dock. Is there anyway to make this work?
Yep... just get a 50A 125/250 "Y" adapter. You just have to manage your peak loads so you don't trip the shore breaker.
Any idea where to find one? Hubbell told me that one doesn't exist
User avatar
km1125
Admiral
Admiral
Posts: 3657
Joined: February 28th, 2017, 6:04 pm
Has thanked: 81 times
Been thanked: 1114 times

Re: 50 amp power y spec

Post by km1125 »

You can verify is this is correct for what you're trying to do, but based on your description I think it is if you use your two shore power cords. There is a different one if you want to use just one shore power cord and have the "Y" at the boat (has reversed male/female connectors). Either way you're still limited to the breaker on the shore service, so one might be more convenient than the other for you.

https://www.amazon.com/Amp-Up-Marine-Sp ... 94&sr=8-10

Not sure why that link doesn't show up... let me try it this way:
https://www.amazon.com/Amp-Up-Marine-Sp ... 94&sr=8-10
User avatar
Geaux Time
Scurvy Dog
Scurvy Dog
Posts: 7
Joined: July 6th, 2022, 11:50 am

Re: 50 amp power y spec

Post by Geaux Time »

Thanks for this info. The female ends look correct (with the 2 kickout posts recepticles on each side), but the male side only appears to have 1 kickout post which would mean thats actually a 50a 125v only male end wouldn't it? The description says exactly what I need though
User avatar
bud37
Admiral
Admiral
Posts: 5182
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 604 times
Been thanked: 1312 times

Re: 50 amp power y spec

Post by bud37 »

Is this what you are looking for ....check out the image...


https://www.marinco.com/en/p/165AY/Y-Ad ... e-To-2-50A
FWIW.....The above is just my opinion.
User avatar
Geaux Time
Scurvy Dog
Scurvy Dog
Posts: 7
Joined: July 6th, 2022, 11:50 am

Re: 50 amp power y spec

Post by Geaux Time »

Going by the description you'd think so but look at the female end. There is only one kickout slot and not 2 like the male plugs out of the boat. With all the Marquis out there I'm thinking there must be a solution
User avatar
Geaux Time
Scurvy Dog
Scurvy Dog
Posts: 7
Joined: July 6th, 2022, 11:50 am

Re: 50 amp power y spec

Post by Geaux Time »

I'm being told that the one kickout indicates a 50A 125 plug and not a 125/250