You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!
Need Help - Leaking Toilet
- tonyp444
- Scurvy Dog
- Posts: 47
- Joined: October 7th, 2023, 9:21 pm
- Has thanked: 48 times
- Been thanked: 10 times
Need Help - Leaking Toilet
I went down to the boat today to find a pretty major leak coming from the toilet on our 325. Any standing water had drained down the shower drain, but the bath mat in there was completely saturated and there was quite a lot of water on the floor in the head.
I had noticed recently that the level in the black water tank seemed to be increasing while the boat was at the dock and the toilet wasn’t being used, but I thought maybe it was just due to the boat rocking back and forth or something.
As far as I can tell, the water pump module on the toilet is broken, or there is some sort of valve in the pump that is stuck open, because water was freely flowing up the flush hose and into the bowl.
The leak that made is way unto the head floor was due to the water coming up the flush hose and backing up into the line from the deodorant reservoir, which eventually overflowed and leaked out onto the floor.
In the process of checking all this out, I also found out our shower sump stopped working (going to post another thread on that)
Here’s a picture of the toilet (Crown model, original from 1996). Unfortunately I don’t have the manual, but I think it’s best I just replace the whole thing anyway.
If you have any suggestions for a simple fix, I’m all ears.
Here is where I need help. In choosing a new toilet, there are two types: one which is designed to be connected to a pressurized fresh water system, and the other which has a water pump to draw water from a raw water intake. When I went into the engine compartment to try to turn off the water, I was expecting just a raw water seacock. The owners manual said that all toilets, regardless of model, were fed by a raw seawater intake. However, when I dug in, that’s not what I found. It seems like the PO plumbed the toilet intake to the fresh water system on the boat, but did it upstream of the water pump, so it is essentially fresh water, but unpressurized. Am I seeing this correctly? Yellow arrows are pointing to the toilet intake hose.
If I’m correct and that is how it is plumbed, then I think I’ll need to use the style of toilet that has a pump and is designed for a raw water intake. It was very obvious that the toilet is not connected to the pressurized water system based on the slow drip of a leak, and because turning the water pump off and draining the water in the lines going to the sinks did not change the flow coming through the toilet flush line at all. I did turn off the red valve upstream of the water pump and toilet intake and that stopped the flow at the toilet.
Thanks so much for any guidance you can provide.
- tonyp444
- Scurvy Dog
- Posts: 47
- Joined: October 7th, 2023, 9:21 pm
- Has thanked: 48 times
- Been thanked: 10 times
Re: Need Help - Leaking Toilet
Isn’t this something our surveyor should have caught?
I’m thinking I should take this opportunity to connect a proper fresh water toilet to the pressurized water system. That would entail removing the tee before the water pump and then I could tee into the pressurized line after the pump, right?
Can I use standard PEX tubing or is this going to be a different diameter? I think I remember reading about that being an issue. I haven’t done any marine plumbing.
- km1125
- Admiral
- Posts: 3500
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 69 times
- Been thanked: 1043 times
Re: Need Help - Leaking Toilet
With no pressure, I'm surprised you were seeing a lot of water flow. Is the level in the water tank a lot higher than the toilet?
- tonyp444
- Scurvy Dog
- Posts: 47
- Joined: October 7th, 2023, 9:21 pm
- Has thanked: 48 times
- Been thanked: 10 times
Re: Need Help - Leaking Toilet
km1125 wrote:Source of the post You're definitely on the right path. YES, it is an issue to connect to the potable water system without any kind of backflow prevention device!
With no pressure, I'm surprised you were seeing a lot of water flow. Is the level in the water tank a lot higher than the toilet?
Yes. In fact, I just put 2 and 2 together - I filled up the fresh water tank right before leaving the boat last time and I’m sure that’s why the toilet leaked when it hadn’t been leaking before. With the toilet intake hose being close to the low point in the boat and the water level being high in the tank, gravity took over. I bet we’d see very little water flow if the fresh water tank was closer to empty.
I answered my other question on the PEX tubing. I bet my water lines from 1996 are 15mm but I’ll confirm tomorrow. In that case I’ll need adapters if I want to use standard 1/2” PEX and fittings. As a novice plumber I think it would make it easy to use SharkBite fittings, but open to suggestions.
I guess I’m glad now that this leak happened so I discovered this issue with the plumbing.
-
- CYO Supporter
- Posts: 5975
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 455 times
- Been thanked: 1671 times
Re: Need Help - Leaking Toilet
- tonyp444
- Scurvy Dog
- Posts: 47
- Joined: October 7th, 2023, 9:21 pm
- Has thanked: 48 times
- Been thanked: 10 times
Re: Need Help - Leaking Toilet
Viper wrote:Source of the post If you’re talking about the grey lines in the pics, they’re more likely to utilize the 1/2” quick connect fittings.
Yes, those are the lines. That would make my life much easier because I’ll need to run a 1/2” nipple to the backflow protection solenoid that will be in the intake line for the new fresh water toilet, so a 1/2” quick connect tee would make it really simple. I’ll check the stamping and take a picture when I’m down there later today. Thanks!
-
- CYO Supporter
- Posts: 5975
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 455 times
- Been thanked: 1671 times
Re: Need Help - Leaking Toilet
They are good toilets that can be completely rebuilt but they are power hogs at just under 40 amps during operation. Having said that, they only take a couple of seconds to evacuate the bowl.
BTW, yours wouldn't be the first toilet I've seen hooked up in that fashion to the fresh water system on a Carver, and the ones I've seen looked factory and always hooked up in the same spot. They may not have been as concerned with siphoning as there's only so much water in a tank versus a raw water hookup.
-
- CYO Supporter
- Posts: 5975
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 455 times
- Been thanked: 1671 times
- tonyp444
- Scurvy Dog
- Posts: 47
- Joined: October 7th, 2023, 9:21 pm
- Has thanked: 48 times
- Been thanked: 10 times
Re: Need Help - Leaking Toilet
Is this CPVC? I didn’t see the material type anywhere in the stamping. If so, looks like the best way to cut the CPVC tubing in place would be to use a “C” style tubing cutter?