Kohler 6.5 esv genny

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
Post Reply
User avatar
tomschauer
Admiral
Admiral
Posts: 2323
Joined: March 28th, 2016, 10:52 pm
Vessel Info: 1998 Carver 355
Suspicious Fishes !
2022 Kawasaki 310X
Location: upper chesapeake bay
Has thanked: 326 times
Been thanked: 602 times

Kohler 6.5 esv genny

Post by tomschauer »

I saw some other posts addressing the issue just experienced. Looks like people were replacing sensors and random parts. Maybe this will save someone some time. It wont save much money because a new board is about $300.

We were out last week and the genny shut off after about 2 hours run time. I thought it had most likely over heated as the impeller most likely was never changed, 110 hrs total run time.
So I bought an impeller, fuel filter and oil filter. changed all this weekend, started up and ran about 30 minutes and shut off again.

Let it sit a bit and tried again. It tried to start but would shut down as soon as the start switch was released. Then it didn't even try to start.

Ok time to actually dig in and figure it out.
Spark, check.
Compression, check.
Fuel, ???
It seems the power to the fuel pump was only 7 volts coming from the control board relay with a good 13 volts coming into the board. Ran power direct to the fuel pump, it starts and runs fine.
Time for a new control board.
Viper
CYO Supporter
CYO Supporter
Posts: 6266
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 475 times
Been thanked: 1791 times

Re: Kohler 6.5 esv genny

Post by Viper »

:down: